(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
Ionizer with flow rate adjustment function that enables extensive, rapid static neutralization.
[Features]
· Covers an extensive static neutralization area with adjustable louver.
· Stable static neutralization performance and easier maintenance.
· 7 types of alarm functions as standard.
· LED indicator can be checked from 2 directions.
· Filter prevents ingress of lint and foreign matter, etc. to the motor and helps reduce issues and short circuits between emitters.
· Automatic balance adjustment function achieves stable offset voltage and reduces adjustment time.
· Automatic cleaning function reduces emitter contamination.
· Replaceable emitter cartridge can be removed in a single action (no tools required).
Part Number
Configured Part Number is shown.
IZF31-N
Fan-Type Ionizer External Appearance
IZF21 external appearance
Model | IZF21-□ | IZF21-P | IZF31-□ | IZF31-P | |
---|---|---|---|---|---|
NPN | PNP | NPN | PNP | ||
Maximum Air Flow | 1.8 m3/min | 4.4 m3/min | |||
Applied Voltage | ±5 kV | ||||
Ion Generation Method | Corona discharge type | ||||
Voltage Application Method | DC type | ||||
Offset Voltage (Ion Balance)* | ±5 V | ||||
Power Supply Voltage | 21.6 to 26.4 V DC (Within 24 V DC ±10%) | ||||
Current Consumption | 0.9 A or less | 1.3 A or less | |||
Input Signal | Ionizer Stop Signal | Connected to 0 V Voltage range: 5 V DC or less Current consumption: 5 mA or less | Connected to +24 V Voltage range: 19 V DC to power supply voltage Current consumption: 5 mA or less | Connected to 0 V Voltage range: 5 V DC or less Current consumption: 5 mA or less | Connected to +24 V Voltage range: 19 V DC to power supply voltage Current consumption: 5 mA or less |
Cleaning Input Signal | |||||
Output Signal | Maintenance Signal | Max. load current: 100 mA Residual voltage: 1 V or less (load current at 100 mA) Max. applied voltage: 26.4 V DC | Max. load current: 100 mA Residual voltage: 1 V or less (load current at 100 mA) | Max. load current: 100 mA Residual voltage: 1 V or less (load current at 100 mA) Max. applied voltage: 26.4 V DC | Max. load current: 100 mA Residual voltage: 1 V or less (load current at 100 mA) |
Error Signal | |||||
Ambient Operating Temperature | Operating: 0 to 50°C, Stored: -10 to 60°C | ||||
Ambient Humidity | Operating, Stored: 35 to 80% RH (no condensation) | ||||
Material | Case: ABS / PBT / Stainless steel, Emitter: Tungsten | ||||
Impact Resistance | 100 m/s2 | ||||
Standards/Directive | CE (EMC directive: 2014/30/EU) |
*Based on ANSI/ESD-STM3.1-2006 standards
Input Voltage | 100 V AC to 240 V AC, 50/60 Hz |
---|---|
Output Voltage | 24 V DC |
Output Current | 1.9 A max |
Ambient Operating Temperature | 0 to 40°C, Stored: -20 to 65°C |
Ambient Humidity | Operating, Stored: 5 to 95% RH (no condensation) |
Weight | 375 g (including AC cord, connector) |
Standards/Directive | CE/cUL |
- | IZF21 | IZF31 |
---|---|---|
Body | 430 g | 605 g |
Bracket | 146 g | 220 g |
Automatic Cleaning Unit | 96 g | 127 g |
Louver | 33 g | 58 g |
Filter | 15 g | 26 g |
IZF21/IZF31 Series display function names and descriptions
No. | Name | Panel Display | Type | Description |
---|---|---|---|---|
1 | Power supply switch | POWER | Switch | Switches power ON and OFF. |
2 | Power supply indicator | PWR | LED (Green/Red) | Green lights up…Power supply is ON Green flashes…Power supply abnormality Red flashes…CPU abnormality |
3 | Static neutralization operation / Incorrect high voltage indicator | ION/HV | LED (Green/Red) | Green lights up…Static neutralization in operation Red lights up…Incorrect high voltage detected Red flashes…CPU abnormality |
4 | Error indicator | ALM | LED (Red) | Red lights up…Fan motor failure or automatic cleaning error detected Red flashes…CPU abnormality |
5 | Maintenance indicator | NDL | LED (Green/Red) | Green lights up…Emitters require cleaning Green flashes…Automatic cleaning in operation Red flashes…Emitter cartridge not mounted correctly or automatic cleaning error or CPU failure detected |
6 | Balance adjustment | ADJUST | Trimmer | Adjusts offset voltage (ion balance). |
7 | Air flow adjustment | BLOW SPEED | Rotary switch | Adjusts fan air flow. |
IZF21/IZF31 Series Wiring Chart
Pin No. | Cable Color | Signal Name | Signal Direction | Description |
---|---|---|---|---|
A1 | Brown | +24 V DC | IN | Connects power supply. |
B1 | ||||
A2 | Blue | 0 V | IN | |
B2 | ||||
A3 | Green | F.G. | - | Ground terminal with a ground resistance of 100Ω or less to use as a reference electric potential of offset voltage. |
B3 | Yellow-green | Ionizer Stop Signal | IN | Signal input to turn fan ventilation and ion generation ON or OFF. NPN type: Connect to 0 V to stop fan and ion generation (operates when disconnected). PNP type: Connect to +24 V DC to stop fan and ion generation (operates when disconnected). |
A4 | Gray | Cleaning signal | IN | Cleaning of emitters starts when automatic cleaning unit is mounted. |
B4 | Yellow | Maintenance Signal | OUT (A-Contact) | Turns ON when cleaning due to emitter contamination and/or replacement due to wear is required or when automatic cleaning is in operation (when an automatic cleaning unit is mounted). Turns OFF during output circuit over current error. |
A5 | Purple | Error Signal | OUT (B Contact) | Turns OFF if there is a power supply failure, incorrect high voltage, fan motor failure, CPU failure, excess current on the output circuit, emitter cartridge mounting failure or automatic cleaning error (when an automatic cleaning unit is mounted) (ON during normal operation). |
B5 | White | - | - | - |
(Unit: mm)
IZF21-□-□□□□ dimensional drawing
(Unit: mm)
Bracket/IZF21-□-□B□□ dimensional drawing
(Unit: mm)
IZF31-□-□□□□ dimensional drawing
(Unit: mm)
End Bracket / IZF31-□-□B□□ dimensional drawing
IZF21/IZF31 Series Wiring Circuit 1
IZF21/IZF31 Series Wiring Circuit 2
*Refer to the catalog for further information on this product.
Part Number |
---|
IZF31-N |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Indicators | Additional Function | Air Flow/Air Consumption Quantity (m3/min) | Ion Balance | Ion Balance Adjusting Function | Power Supply | Options | Accessories/options: ordered separately | I/O specifications | Automatic cleaning unit / louver | Model |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | Fan Type | Charged/Discharged Status / Cleaning Lamp / Fan Error Lamp | Air Volume Adjustment / Error Signal Output | 4.4 | ±5V | Manual | DC24V | - | None | NPN input/output | None | - |
Loading...
Please check the type/dimensions/specifications of the part IZF31-N in the Fan Type Ionizer, IZF21/IZF31 Series series.
Part Number |
---|
IZF21-BSU |
IZF21-BU |
IZF21-BW |
IZF31-NB |
IZF31-NBS |
IZF31-NBSU |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Type | Indicators | Additional Function | Air Flow/Air Consumption Quantity (m3/min) | Ion Balance | Ion Balance Adjusting Function | Power Supply | Options | Accessories/options: ordered separately | I/O specifications | Automatic cleaning unit / louver | Model |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SGD 1,725.38 | 1 Piece(s) | 32 Day(s) | Fan Type | Charged/Discharged Status / Cleaning Lamp / Fan Error Lamp | Air Volume Adjustment / Air Filter / Error Signal Output | 1.8 | ±5V | Manual | DC24V | - | With filter / With power supply cable (3 m) / With bracket | NPN input/output | With automatic cleaning unit | - | ||
SGD 1,422.40 | 1 Piece(s) | 32 Day(s) | Fan Type | Charged/Discharged Status / Cleaning Lamp / Fan Error Lamp | Air Volume Adjustment / Air Filter / Error Signal Output | 1.8 | ±5V | Manual | DC24V | - | With filter / With power supply cable (3 m) / With bracket | NPN input/output | None | - | ||
SGD 1,400.00 | 1 Piece(s) | 32 Day(s) | Fan Type | Charged/Discharged Status / Cleaning Lamp / Fan Error Lamp | Air Volume Adjustment / Error Signal Output | 1.8 | ±5V | Manual | DC24V | - | With power supply cable (3 m) / With bracket | NPN input/output | With adjustable louver | - | ||
- | 1 Piece(s) | Quote | Fan Type | Charged/Discharged Status / Cleaning Lamp / Fan Error Lamp | Air Volume Adjustment / Error Signal Output | 4.4 | ±5V | Manual | DC24V | - | With bracket | NPN input/output | None | - | ||
SGD 1,741.25 | 1 Piece(s) | 32 Day(s) | Fan Type | Charged/Discharged Status / Cleaning Lamp / Fan Error Lamp | Air Volume Adjustment / Error Signal Output | 4.4 | ±5V | Manual | DC24V | - | With bracket | NPN input/output | With automatic cleaning unit | - | ||
- | 1 Piece(s) | Quote | Fan Type | Charged/Discharged Status / Cleaning Lamp / Fan Error Lamp | Air Volume Adjustment / Air Filter / Error Signal Output | 4.4 | ±5V | Manual | DC24V | - | With filter / With bracket | NPN input/output | With automatic cleaning unit | - |
How can we improve?
How can we improve?