(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Normally Closed Type High Vacuum Solenoid Valve XSA Series (XSA1/XSA2/XSA3) (XSA2-22P-5C2)

Normally Closed Type High Vacuum Solenoid Valve XSA Series (XSA1/XSA2/XSA3) XSA2-22P-5C2

A normally closed type high vacuum solenoid valve with reduced particulate matter and improved sealing performance.
[Features]
・ Flame-retardant (UL94 V-0 compliant)
・ Two types of fittings (face seal fittings / compression fittings) and female threads (Rc, NPT) are available
・ By moving the spring from the sliding part of the armature to the body part, dust generation due to contact with the spring has been reduced
・ Securely seals with a large spring force
・ Power consumption *: 4.5 W (size 1) / 7 W (size 2) / 10.5 W (Size 3) (* For DC specifications / B type. )
・ Operating temperature range: 5 to 60℃

(i)Caution

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2/MG types, etc., are already available.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • The product images may be representative images only. Refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

XSA2-22P-5C2

Normally Closed Type High Vacuum Solenoid Valve XSA Series Specifications

Face seal fitting appearance

Face seal fitting appearance

A fitting with a high sealing performance in everything from vacuum pressure to positive pressure that forms a seal by placing a metal gasket at the end of the sleeve and the tightening of the nut.

Compression fitting external appearance

Compression fitting external appearance

A self-aligning tube fitting that uses ferrule rings which align and connect with the tubing when the nut is tightened.

Female thread (Rc, NPT) external appearance

Female thread (Rc, NPT) external appearance

ModelXSA1-11
XSA1-12
XSA1-21
XSA1-22
XSA2-22XSA2-32XSA2-43 Note 3:XSA3-32
XSA3-33
XSA3-43
ActionNormally closed
FluidsAir, inert gas
Orifice Diameter (mm) ø234.564.56
Withstand Pressure MPa (G)1.5
Minimum Operating Pressure Pa (abs) / OUT Side1 × 10-6
Maximum Operating Pressure MPa (G) / IN Side1.0
Maximum Operating Pressure Differential MPa Note 1:0.80.31.00.30.10.80.3
Reverse Pressure Potential MPa (G) Note 2:0.50.250.40.20.050.20.15
Amount of leakage Pa·m3/s Note 4:Internal1.3 × 10-9
External1.3 × 10-11
Piping Connection MethodFace seal fitting / compression fitting / (Rc, NPT) female thread
Connection SizeFace Seal Fitting (Inches)
Compression Fitting (Inches)
1/43/81/43/8
(Rc, NPT) female thread1/81/4-3/8
Ambient Temperature and Operating Fluid Temperature (°C)5 to 60
Rated Voltage Note 5:100/110/200/220/230/240/24/48 V AC, 12/24 V DC
Power Consumption (W) Note 6:DC4.5710.5
Apparent Power (VA) Note 6:AC79.512
Coil Temperature Rise (°C) Note 7:DC505565
AC607070
Allowable Voltage Fluctuation±10% or less of rated voltage
Allowable Leakage VoltageDC2% or less of rated voltage
AC5% or less of rated voltage
Coil Insulation TypeClass B
Weight kg Note 8:Face Seal Fitting0.280.410.420.530.62
Compression Fitting0.280.410.420.530.55
(Rc, NPT) female thread0.330.53-0.740.74

Note 1: The operating pressure differential is the difference between port 1 (high pressure side) and port 2 (low pressure side).
Example: At 0.3 MPa, port 2 is vacuumed (1 Torr or less), while port 1 can be pressurized up to 0.2 MPa (G).
Note 2: The reverse potential pressure indicates the pressure which can be applied from port 2 when port 1 is at atmospheric pressure.
Note 3: Face seal fitting / compression fitting only.
Note 4: Amount of leakage when the ambient temperature is at 20°C and there is 0.1 MPa of differential pressure (gas permeation not included).
Note 5: AC types are all equipped with a full-wave rectifier.
Note 6: Power consumption and apparent power are values at an ambient temperature of 20°C and with rated voltage applied. (Variation range: ±10%)
Note 7: Value at an ambient temperature of 20°C and with rated voltage applied. However, this value depends on the ambient environment.
Note 8: This value is for the grommet type.

Face Seal Fitting / Compression Fitting Flow Rate Characteristics

-XSA1-12XSA1-22XSA2-22XSA2-32XSA2-43XSA3-32XSA3-43
Flow Rate CharacteristicsC [dm3/(s·bar)]0.551.071.071.512.781.542.89
b0.410.360.340.240.210.240.21

Female Thread (Rc, NPT) Flow Rate Characteristics

-XSA1-11XSA1-21XSA2-22XSA2-32XSA3-33XSA3-43
Flow Rate CharacteristicsC [dm3/(s·bar)]0.541.141.142.232.373.50
b0.360.390.420.380.400.15

Face Seal Fitting and Compression Fitting Drawing

 

(Unit: mm)

 

Grommet: G dimensional drawing (lower left: no spacer / lower right: with spacer)

Grommet: G dimensional drawing (lower left: no spacer / lower right: with spacer)

Grommet: GS dimensional drawing

Grommet: GS dimensional drawing

Conduit: C dimensional drawing

Conduit: C dimensional drawing

Flat terminal: F dimensional drawing (left: terminal)

Flat terminal: F dimensional drawing (left: terminal)

DIN terminal: D dimensional drawing

DIN terminal: D dimensional drawing

Terminal: T dimensional drawing

Terminal: T dimensional drawing

ModelABBsCDEFLMP
[inch]
XSA1-□2S22552463308.520381/4
XSA1-□2V50-
XSA2-□2S256331.573.53511.522510
XSA2-□2V56-
XSA2-43S64.5313/8
XSA2-43V67-78
XSA3-32S6331.54024.51/4
XSA3-32V56-
XSA3-43S64.5313/8
XSA3-43V67-82.5
ModelGrommet: GGrommet: GSConduit: CFlat Terminal: FDIN Terminal: DTerminal: T
GHGHGHGHGHJGHJ
XSA1-□2S2753.5304047.547.52353.564.545.552.599.547.568.5
XSA1-□2V
XSA2-□2S29.56332.549.5505725.5636755551025771
XSA2-□2V
XSA2-43S
XSA2-43V67.55461.567.559.561.5
XSA3-32S323552.52869.557.5104.573.5
XSA3-32V
XSA3-43S
XSA3-43V7258.566726466

Product Structure/Operation

Structure and operation of normally closed type high vacuum solenoid valve, XSA Series

Structure and operation of normally closed type high vacuum solenoid valve, XSA Series

NumberNameMaterial
1Solenoid CoilCu + Fe + resin
2Fixed Iron CoreFe
3TubeSUS*
4Residual (Seat)PET*
5Movable Armature Iron Core Assembly’FKM, SUS, resin (PPS)*
6SpringSUS*
7BodySUS*
8O-ringFKM*
9SpacerAl
  • *Parts in contact with gas

Options Descriptions

(9) Spacer (face seal fitting / compression fitting only): The spacer is used to raise the body when fastening it onto a flat area.

Working Principle

By energizing the solenoid coil (1), the armature movable iron core assembly’ (5) overcomes the composite force, which consists of the force acting on the poppet due to differential pressure and the reactive force of the spring (6), and is suctioned to the fixed iron core (2), thus opening the poppet.
When the energization of the solenoid coil (1) is stopped, the armature movable iron core assembly’ (5) separates from the fixed iron core (2) under the reactive force of the spring (6), thus closing the poppet.

Notes

  • *Cannot be used for emergency shut-off valves, etc. The valve described in the catalog is not designed to be used as a safety valve such as an emergency shut-off valve. For such systems, take other measures that will reliably secure safety.
  • *Long-term continuous energization will cause the solenoid coil to generate heat. Avoid use in airtight containers. Install in locations with good ventilation. Do not touch the solenoid valve during or immediately after energization.
  • *Refer to the manufacturer's catalog for product information not detailed above.
Part Number
XSA2-22P-5C2
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPipe Port Type Plumbing Thread Nominal Voltage Electrical Entry Method Orifice Diameter
(ø)
Spacer Valve size Electrical Entry Direction
(°)

-

1 Piece(s) Quote [Rc] Rc1/4DC24VConduit (with surge voltage suppressor)3NoneSize 2None

Loading...

  1. 1

Basic Information

Type High Vacuum Solenoid Application Single Use Mounting Orientation Direct
Number of Ports 2-Port Valve Solenoid Type Single Switching Type 2-Position Normally Closed
Driving Type Directly Operated Seal Type Bellows Seal

Please check the type/dimensions/specifications of the part XSA2-22P-5C2 in the Normally Closed Type High Vacuum Solenoid Valve XSA Series (XSA1/XSA2/XSA3) series.

Similar Part Numbers

Part Number
XSA1-11N-5F2
XSA1-11N-5G2
XSA1-11P-1DL2
XSA2-22P-5D2
XSA2-22P-5DL2
XSA2-22P-5G2
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPipe Port Type Plumbing Thread Nominal Voltage Electrical Entry Method Orifice Diameter
(ø)
Spacer Valve size Electrical Entry Direction
(°)

-

1 Piece(s) Quote [NPT] NPT1/8DC24VFlat terminal2NoneSize 1None

SGD 360.15

1 Piece(s) 32 Day(s) [NPT] NPT1/8DC24VGrommet2NoneSize 1None

-

1 Piece(s) Quote [Rc] Rc1/8AC100VDIN terminal with light (with surge voltage suppressor)2NoneSize 1None

SGD 404.25

1 Piece(s) 32 Day(s) [Rc] Rc1/4DC24VDIN terminal (with surge voltage suppressor)3NoneSize 2None

-

1 Piece(s) Quote [Rc] Rc1/4DC24VDIN terminal with light (with surge voltage suppressor)3NoneSize 2None

-

1 Piece(s) Quote [Rc] Rc1/4DC24VGrommet3NoneSize 2None

Tech Support