(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
[Features]
· A pressure switch function has been added to the gauge
· The pressure switch has a light to confirm operation
· The pressure gauge includes a limit indicator
· Used to confirm supply pressure
Part Number
Configured Part Number is shown.
GP46-10-02L2-C2-X201
Pressure Gauge With Switch GP46 external appearance
Circuit example
Model | GP46 | ||
---|---|---|---|
Pressure gauge | Shape | Back side thread | |
Ambient and fluid temperature | -5 to +60°C (no freezing) | ||
Indicated pressure range | 0 to 1.0 MPa | ||
Port size*1 | R1/8, R1/4 (option M: with M5 female thread) | ||
Fluid*2*6 | Air | ||
Indication precision*7) | ±0.03 MPa | ||
Pressure switch | Setting range*3*4 | 0.1 to 0.8 MPa | |
Hysteresis | 0.07 MPa or less | ||
Pointer error*5 | ±0.05 MPa (5 to 40°C) ±0.08 MPa (-5 to +60°C) (no freezing) | ||
Contact | With light: 1a (normally open) Without light: 1ab (normally open / normally closed) | ||
Wiring | Lead wire: 300 mm long | ||
Indicator light | AC | Neon light | |
DC | Light-emitting diode (LED) | ||
Clear cover | Part number: G46-00-00-3 | ||
Attachment: with cover ring assembly | C | Part number: 1305104-4A | |
C2 | Part number: 1305104-10A | ||
Weight (kg) | 0.12 |
*1: When mounting the pressure gauge, take care not to over-tighten. Excessive tightening will cause damage. Use pipe tape for sealing.
*2: Water is not an acceptable fluid. Before using other fluids, please contact the manufacturer's support center as there may be a corrosion problem.
*3: The set value of the pressure switch is indicated by the pointer (green). It is the point where the circuit between N.O. (white) and COM (black) is turned off during pressure decrease. To set the value, turn the needle in the clockwise direction to the correct value. When setting, if the desired set position has been passed, turn the needle in the counterclockwise direction back again beyond the desired value and then set it again.
*4: Make sure to provide a minimum difference of 0.1 MPa between the set pressure and the operating pressure (including the pressure drop). If the difference is smaller, it could lead to improper operation. See the manufacturer's catalog for details on how to set the setting needle. Note that the operating pressure should be the sum of the pressure of the setting needle error (±0.03 MPa), the hysteresis (0.07 MPa), and the display accuracy (±0.05 MPa) on the set pressure value, or the circuit between N.O. (white) and COM (black) may not turn ON while pressure is increasing.
*5: Maximum error value: Add the pressure gauge indicator error to the setting needle error.
*6: Take care to avoid freezing. This may result in a malfunction.
*7: The guaranteed temperature range is 23°C±5°C.
Circuit diagram without indicator light
Circuit diagram with indicator light (top: 110, 220 V AC, bottom: 24 V DC)
*The arrow in the diagram indicates the direction of the pressure increase. The light turns off at or above the set pressure and turns on when it is below the set pressure.
Model | Pressure range*1 | Indication unit | Port size | Note |
---|---|---|---|---|
MPa | ||||
GP46-10-01 to 02 (-Q) | 0 to 1.0 | MPa | R 1/8 R 1/4 | - |
GP46-10-01 to 02L2 | ||||
GP46-10-01 to 02L5 (-Q) |
*1: Do not apply pressure more than the maximum display pressure. This may result in a malfunction.
Model | Pressure range*1 | Indication unit | Port size | Note | |
---|---|---|---|---|---|
MPa | psi | ||||
GP46-10-01 to 02-X201 | 0 to 1.0 | - | MPa | R 1/8 R 1/4 | Lead wire length 3 m |
GP46-10-01 to 02L2-X201 | |||||
GP46-10-01 to 02L5-X201 |
*1: Do not apply pressure more than the maximum display pressure. This may result in a malfunction.
Load | Load resistance | ||
---|---|---|---|
Rated voltage | 30 V DC | 125 V AC | 250 V AC |
Operating current range | 0.01 to 0.5 A | 0.01 to 0.3 A | 0.01 to 0.2 A |
*The dimensions within ( ) are for port size R1⁄4
(Unit: mm)
GP46-10-01 to 02 (M) (L2, 5) dimensional drawing
(Unit: mm)
With cover ring assembly (for panel mount) GP46-10-01 to 02 (M) (L2, 5)-C dimensional drawing
Method 1
(1) Before setting the limit indicator and the (green) setting needle, turn the cover counterclockwise (approximately 6 to 7 mm) until it stops. Then, remove by pulling it towards you.
Method 2
(2) Use a flat head screwdriver (with a 2.9‑mm blade width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial plate.
Method 3
(3) Before setting the setting needle, use a flat head screwdriver (with a 2.9‑mm blade width) to turn the setting screw and set the setting needle to the set pressure.
Turning the screw
Method 4
(4) After completing the setting, replace the cover. Fit the cover by aligning the cutout in the cover to the groove on the top of the black case. Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make sure that the matching mark on the cover is aligned with the groove on the top of the case.
Part Number |
---|
GP46-10-02L2-C2-X201 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Outer Diameter (φ) | Connection screw | Option | Special Configurations | Indication lamp addition symbol | Attachment |
---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 57 | R 1/4 | None | Lead wire length 3 m | With neon light / 100 to 220 V AC common | Clear cover has protrusion (Clear cover is removable). The wrench flats protrude |
Loading...
Type | Other Pressure Gauge / Peripheral Accessories | Maximum Indicated Pressure(Mpa) | 1 | Shape | Back side thread |
---|---|---|---|---|---|
Maximum Indicated Pressure | 1.0 MPa |
Please check the type/dimensions/specifications of the part GP46-10-02L2-C2-X201 in the Pressure Gauge With Switch GP46 Series series.
Part Number |
---|
GP46-10-01-Q |
GP46-10-01-X201 |
GP46-10-01L2 |
GP46-10-02L5 |
GP46-10-02L5-C |
GP46-10-02L5-C-X201 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Outer Diameter (φ) | Connection screw | Option | Special Configurations | Indication lamp addition symbol | Attachment |
---|---|---|---|---|---|---|---|---|---|---|
SGD 97.88 | 1 Piece(s) | 32 Day(s) | 42.5 | R 1⁄8 | None | CE marked | Without light | Without cover ring assembly | ||
SGD 79.68 | 1 Piece(s) | 32 Day(s) | 42.5 | R 1⁄8 | None | Lead wire length 3 m | Without light | Without cover ring assembly | ||
SGD 72.45 | 1 Piece(s) | 32 Day(s) | 42.5 | R 1⁄8 | None | None | With neon light / 100 to 220 V AC common | Without cover ring assembly | ||
SGD 72.45 | 1 Piece(s) | 32 Day(s) | 42.5 | R1/4 | None | None | Light-emitting diode / 24 V DC | Without cover ring assembly | ||
SGD 78.63 | 1 Piece(s) | 32 Day(s) | 57 | R1/4 | None | None | Light-emitting diode / 24 V DC | Clear cover has no protrusion (clear cover cannot be removed) | ||
SGD 85.87 | 1 Piece(s) | 32 Day(s) | 57 | R1/4 | None | Lead wire length 3 m | Light-emitting diode / 24 V DC | Clear cover has no protrusion (clear cover cannot be removed) |
How can we improve?