Vacuum/Release Unit VQD1000-V Series (VQD1000-VC-01-6)

Vacuum/Release Unit VQD1000-V Series VQD1000-VC-01-6

A vacuum/release module that does not require a restrictor circuit for release air.
[Features]
· Response speed 13 msec (at 500 mm*).
· 18.5 msec (at 1,000 mm*).
*Distance from module to the workpiece.
· Smooth detachment of workpieces without over-shoot.
· No workpiece blowout caused by release air.
· No need to adjust the timing when switching between vacuum and positive pressure (single signal control).
· N.O. specification (vacuum adhesion type when not energized) and N.C. specification (vacuum shut-off type when not energized) can be selected.

(i)Caution

  • Refer to the manufacturer's catalog for specifications and material details.
  • The product images may be representative images only. Refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

VQD1000-VC-01-6

Vacuum/Release Unit VQD1000-V Series Specifications

VQD1000-V Series external appearance and structure

VQD1000-V Series external appearance and structure

Specifications

Valve SpecificationsValve StructureDirect operated poppet type
Usable FluidsAir
Operating Pressure RangeSuction (Negative Pressure)0 to -100 kPa
Release (Positive Pressure)0 to 0.7 MPa
Response TimeN.O. SpecificationsSuction (OFF)2 ±1 msec
Release (ON)4 ±1 msec
N.C. SpecificationsSuction (ON)4 ±1 msec
Release (OFF)2 ±1 msec
Suction Flow Rate / Sonic Conductance16 L/min / 0.27 dm3/(s·bar)
Manual OperationNon-locking push type
Impact/Vibration Resistance150/30 m/s2
Mounting OrientationFree
EnclosureDust-proof
Electrical SpecificationsCoil Rated Voltage24, 12 V DC
Allowable Rated Voltage Fluctuations±10% of rated voltage
Coil Insulation TypeClass B equivalent
Power ConsumptionVQD1151W (For Switching)3.2 W energy-saving type (startup: 3.2 W, holding: 1.0 W)
Electrical EntryL-type, M-type plug connector (with light / surge voltage suppressor)

Drawing

 

(Unit: mm)

 

VQD1000-V Series dimensional drawing 1

VQD1000-V Series dimensional drawing 1

VQD1000-V Series dimensional drawing 2

VQD1000-V Series dimensional drawing 2

VQD1000-V Series dimensional drawing 3

VQD1000-V Series dimensional drawing 3

Dimensions in parenthesis are for the VQD1000-V(C)L-□□ / tank volume: 3.2 cm3.

L: Dimensions Table

VQD1000-V(C)-□□ / standard type: tank capacity 0.8 cm3

Ln
12345678910
L123344556677889100111122
L21728395061728394105116

General type: L1 = 11n + 12, L2 = 11n + 6 (max. 10 stations)

VQD1000-V(C)L-□□ / tank capacity 3.2 cm3

Ln
12345678910
L125364758698091102113124
L21930415263748596107118

General type: L1 = 11n + 14, L2 = 11n + 8 (max. 10 stations)

Replacement Parts

Replacement parts structural drawing

Replacement parts structural drawing

  • 1. Solenoid valve for switching
  • 2. Solenoid valve for release air charging (*A port pressurized filling specifications. Using a standard product may cause external leakage.)
  • 3. Manifold base module
  • 4. Blanking plate assembly (*The blanking plate assemblies for the solenoid valve for switching and solenoid valve for release air charging are each 1 set.)

Product Weight (Calculation)

  • VQD1000-V(C): W = 80n + 31
  • VQD1000-V(C)L: W = 84n + 49

W: weight (g)
n: number of stations

Working Principle (N.O. Specifications)

When not energized (vacuum suction)

When not energized (vacuum suction)

Two solenoid valves are de-energized simultaneously.
Release air is charged while the workpiece is being held.

When energized (release → shut-off)

When energized (release → shut-off)

Two solenoid valves are energized simultaneously.
The release air is discharged, the pressure matches that of the atmosphere, and the workpiece is smoothly released.

Product Specific Notes

Manual Operation

VQD1151W-□ (for switching)

VQD1151W-□ (for switching)

· Non-locking push type (tool required)
If pressed until it reaches the direction of the arrow (approx. 0.5 mm) it will turn ON. Release to turn OFF.

*If using manual operation, connected devices will operate. Check for dangers before proceeding.

Wiring Specifications

10-VQ110-□-X46 (for release air charging)

10-VQ110-□-X46 (for release air charging)

The figure shows the VQD1151W (energy-saving type). Current consumption when holding is reduced by the circuit, helping save power.

Using the Plug Connector

  • To attach a connector, hold the lever and connector unit between your fingers and insert straight into the pins. Push the claw of the lever into the groove in the cover to lock.
  • To detach a connector, remove the claw from the groove by pushing down the lever with your thumb and then pull the connector straight out.
Connector removal

Connector removal

*Do not use excessive force when pulling the lead wire. Doing so may cause contact failure or disconnection.

Notes

  • *Refer to the manufacturer's catalog for product information not detailed above.
  • The product images are representative images only.
Part Number
VQD1000-VC-01-6
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipElectrical entry Light/surge voltage suppressor Solenoid valve rated voltage CE-marked Valve type Release air tank capacity
(cm3)
Number of stations Number of blankings

-

1 Piece(s) Quote L-type plug connectorWith light/surge voltage suppressor12 V DC-N.C. Specifications0.81 stationWithout blanking

Loading...

  1. 1

Basic Information

Type Unit Additional Function Valves For Vacuum Generation / Vacuum Destructive Valve Vacuum Port Connecting Port Shape M5
Air Supply Port Connecting Port Shape M5 Application Manifolds Suction Flow(l/min) 16

Please check the type/dimensions/specifications of the part VQD1000-VC-01-6 in the Vacuum/Release Unit VQD1000-V Series series.

Similar Part Numbers

Part Number
VQD1000-V-01-5M
VQD1000-V-01-5M-Q
VQD1000-V-01-5MO
VQD1000-VC-02-5
VQD1000-VC-02-5-B1
VQD1000-VC-02-5-B1-Q
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipElectrical entry Light/surge voltage suppressor Solenoid valve rated voltage CE-marked Valve type Release air tank capacity
(cm3)
Number of stations Number of blankings

-

1 Piece(s) Quote M-type plug connectorWith light/surge voltage suppressor24 V DC-N.O. Specifications0.81 stationWithout blanking

-

1 Piece(s) Quote M-type plug connectorWith light/surge voltage suppressor24 V DCCE-markedN.O. Specifications0.81 stationWithout blanking

-

1 Piece(s) Quote M-type without plug connectorWith light/surge voltage suppressor24 V DC-N.O. Specifications0.81 stationWithout blanking

SGD 395.62

1 Piece(s) 32 Day(s) L-type plug connectorWith light/surge voltage suppressor24 V DC-N.C. Specifications0.82 stationsWithout blanking

-

1 Piece(s) Quote L-type plug connectorWith light/surge voltage suppressor24 V DC-N.C. Specifications0.82 stations1 set

-

1 Piece(s) Quote L-type plug connectorWith light/surge voltage suppressor24 V DCCE-markedN.C. Specifications0.82 stations1 set

Tech Support