(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Thermo-Chiller Standard Type Water Cooled 200 V / 400 V Specification HRSH090 Series (Part Numbers)

Thermo-Chiller Standard Type Water Cooled 200 V / 400 V Specification HRSH090 Series

Thermo-Chiller with a water-cooled refrigeration system.
[Features]
· With a high temperature stability of ±0.5°C due to a precise temperature control method that uses an expansion valve and a temperature sensor.
· With a compact tank.
· Power supply: Three-phase 200 V AC (50 Hz) / Three-phase 200 to 230 V AC (60 Hz).
· Set temperature range: 5 to 35°C
· Maximum ambient operating temperature: 45°C.
· RoHS compliant.

(i)Caution

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis
    CQ2/MG types, etc., are already available.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis
    *The information above is correct as of October 2018
  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Thermo-Chiller Standard Type Water-Cooled 200 V Specification HRS090 Series Specifications

HRS090 series external appearance

HRS090 series external appearance

ModelHRS090-W□-20-□
Cooling MethodWater-cooled refrigeration type
RefrigerantR410A (HFC)
Refrigerant Charge (kg)1.15
Control MethodPID control
Ambient Operating Temperature / Humidity / Altitude*1 *2Temperature: 5 to 45°C, Humidity: 30 to 70%, Altitude: Less than 3,000 m
Circulating Fluid SystemCirculating Fluid*3Clear water, 15% ethylene glycol aqueous solution, deionized water (pure water)
Set Temperature Range*2 (°C)5 to 35
Cooling Capacity 50/60 Hz*4 (kW)9.0/10.5
Heating Capacity*5 (kW)1.7/2.2
Temperature Stability*6 (°C)±0.5
Pump CapacityRated Flow Rate 50/60 Hz (Discharge Outlet)*7 (L/min)29/45
Maximum Flow Rate 50/60 Hz (L/min)55/68
Maximum Pump Head (m)50
Minimum Required Flow Rate 50/60 Hz*8 (L/min)29/45
Tank Capacity (L)18
Circulating Fluid Outlet, Circulating Fluid Inlet Pipe Connection Port DiameterRc 1 (symbol F: G 1, symbol N: NPT 1)
Drain Port Pipe Connection Port DiameterRc 1/4 (symbol F: G 1/4, symbol N: NPT 1/4)
Fluid Contacting Parts MaterialStainless steel, copper (heat exchanger brazing), brass, bronze, PTFE
FKM, EPDM, PVC, NBR, POM, PE, PP, carbon, ceramic
Heat-Dissipating Water SystemTemperature Range (°C)5 to 40
Pressure Range (MPa)0.3 to 0.5
Required Flow Rate 50/60 Hz (L/min)25/25
Inlet-Outlet Pressure Differential of Heat-Dissipating Water (MPa)0.3 or more
Heat-Dissipating Water Inlet, Heat-Dissipating Water Outlet Pipe Connection Port DiameterRc 1/2 (symbol F: G 1/2, symbol N: NPT 1/2)
Fluid Contacting Parts MaterialStainless steel, copper (heat exchanger brazing), bronze, brass, PTFE, NBR, EPDM
Electrical SystemsPower SupplyThree-phase 200 V AC (50 Hz), three-phase 200 to 230 V AC (60 Hz)
Allowable voltage variation ±10% (no continuous voltage variation)
Compatible Earth Leakage Circuit Breaker*9Rated Current (A)30
Current Sensitivity (mA)30
Rated Operating Current 50/60 Hz*6 (A)13/14
Rated Power Consumption 50/60 Hz*6 kW (kVA)3.3/4.2 (4.4/4.9)
Noise Level (Front 1 m, Height 1 m)*6 (dB [A])65
AccessoriesAlarm code list sticker 2 pcs. (1 Japanese, 1 English)
Operation manual (for installation and operation) 2 pcs. (1 Japanese, 1 English)
Y-strainer (40 mesh) 25A, barrel nipple 25A
Anchor bolt mounting brackets 2 pcs. (including M10 bolts 4 pcs.)*10
Weight (Dry State) (kg)Approx. 124

*1: Use in a condensation-free environment.
*2: If the ambient operating temperature or circulating fluid temperature is below 10°C, use 15% ethylene glycol aqueous solution. In addition, if there is a possibility that the heat dissipating water could freeze, make sure to drain the heat-dissipating water from the heat-dissipating circuit.
*3: Use circulating fluid that meets the following conditions. In addition, if there is a possibility that the heat dissipating water could freeze, make sure to drain the heat-dissipating water from the heat-dissipating circuit.
  Clear water: Japan Refrigeration and Air Conditioning Industry Association Water Quality Standards (JRA GL-02-1994)
  15% ethylene glycol aqueous solution: Diluted with clear water, no preservatives or additives
  Deionized water (pure water): Electrical conductivity 1 μS/cm or more (electrical resistance 1 MΩ/cm or less)
*4: 1. Heat-dissipating water temperature: 32°C, 2. Circulating fluid: clear water, 3. Circulating fluid temperature: 20°C, 4. Circulating fluid flow rate: rated flow rate, 5. Power supply: 200/400 V AC
*5: 1. Heat-dissipating water temperature: 32°C, 2. Circulating fluid: clear water, 3. Circulating fluid flow rate: rated flow rate, 4. Power supply: 200/400 V AC
*6: 1. Heat-dissipating water temperature: 32°C, 2. Circulating fluid: clear water, 3. Circulating fluid temperature: 20°C, 4. Load: listed cooling capacity, 5. Circulating fluid flow rate: rated flow rate, 6. Power supply: 200/400 V AC, 7. Pipe length: shortest
*7: When circulating fluid outlet pressure = 0.5 MPa
*8: Flow rate necessary to maintain cooling capacity and keep the circulating fluid outlet pressure at 0.5 MPa or less. Install bypass piping when below the minimum required flow rate.
*9: To be provided by the customer. Option B [With earth leakage circuit breaker] has the described earth leakage circuit breaker built in.
*10: The anchor bolt fixing brackets (M10 bolts 4 pcs.) are used for fixing to wooden skids when packaging the Thermo-Chiller. Anchor bolts are not included.

Cooling capacity

HRS090-W-20 (50 Hz) cooling capacity table

HRS090-W-20 (50 Hz) cooling capacity table

HRS090-W-20 (60 Hz) cooling capacity table

HRS090-W-20 (60 Hz) cooling capacity table

Pump Capacity

HRS090-W-20 pump capacity

HRS090-W-20 pump capacity

Mechanical seal details

Mechanical seal details

Notes

*The pump used in the Thermo-Chiller HRS090 Series uses a mechanical seal with a fixed ring and a rotating ring in the shaft seal. If foreign matter enters the gap in the seal, it could cause issues such as seal leakage, pump lock, etc., so it is highly recommended that a particle filter is installed on the chiller return piping.

Dimensions

 

(Unit: mm)

 

HRS090-□-20 dimensions/diagram

HRS090-□-20 dimensions/diagram

*1: For water-cooled versions there is no dust-proof filter.
*2: The 400 V specification comes as option -B [With earth leakage circuit breaker] as standard.

Anchor bolt fixing position (water-cooled type)

Anchor bolt fixing position (water-cooled type)

Recommended External Piping Flow

As shown below, an external piping flow is recommended

External piping flow

External piping flow

No.NameSizeRecommended Part NumberNotes
1ValveRc 1/2--
2ValveRc 1--
3Y-strainerRc 1
#40
AccessoriesInstall either the strainer or filter. If there is a risk of contaminants of 20 μm or more entering the supply, install a particle filter. The recommended filter is HRS-PF005 (sold separately).
FilterRc 1
20 μm
HRS-PF005*
4Flow meter--Prepare a flow meter with an appropriate flow rate range.
5Valve (Thermo-Chiller part)Rc1/4--
6Pressure gauge0 to 1.0 MPa--
7Y-strainerRc 1/2
#40
-Install either the strainer or filter. If there is a risk of contaminants of 20 μm or more entering the supply, select and prepare a particle filter.
FilterRc 1/2
20 μm
-
8ValveRc3/8--
9Y-strainerRc3/8
#40
-Install either the strainer or filter. If there is a risk of contaminants of 20 μm or more entering the supply, install a particle filter.
FilterRc3/8
20 μm
FQ1011N-10-T020-B-X61*

*The above filter cannot be directly connected to the Thermo-Chiller. Install it in the user's piping system.

Cable Specifications

Power Supply Cable Specifications

Compatible ModelThermo-Chiller Rated ValuePower Supply Cable Example
Power SupplyCompatible Breaker Rated CurrentTerminal Block Screw DiameterCable SizeThermo-Chiller Side Crimp Terminal
HRS090-□□-20Three-phase 200 V AC (50 Hz)
Three-phase 200 to 230 V AC (60 Hz)
30 AM54 cores × 5.5 mm²
(4 cores × AWG10)
*Includes ground wire
R5.5-5
  • *The cable specification is an example using two types of vinyl insulated wires with a continuous allowable operating temperature of 70°C at 600 V, at an ambient temperature of 30°C. Choose the correct size of cable for the actual operating environment.
Power supply cable external appearance

Power supply cable external appearance

Signal Cable Specifications

Terminal SpecificationsCable Specifications
Terminal Block Screw DiameterRecommended crimp terminal0.75 mm² (AWG18)
Shielded cable
M3Y-type crimp terminal
1.25Y-3

Operation Display Panel

The basic operation of this product is carried out using the operation display panel on the front of the product.

Operation Display Panel external appearance

Operation Display Panel external appearance

  • *For information other than the above, please refer to the catalog.
  • *Product pictures are representative images.
Part Number
HRS090-W-20
HRS090-W-20-B
HRS090-W-20-BJ
HRS090-W-20-BJM
HRS090-W-20-BM
HRS090-W-20-J
HRS090-W-20-JM
HRS090-W-20-M
HRS090-W-20-W
HRS090-W-40
HRS090-W-40-J
HRS090-W-40-JM
HRS090-W-40-M
HRS090-WF-20
HRS090-WF-20-B
HRS090-WF-20-BJ
HRS090-WF-20-BJM
HRS090-WF-40
HRS090-WN-20
HRS090-WN-20-B
HRS090-WN-20-BJ
HRS090-WN-20-BJW
HRS090-WN-20-BM
HRS090-WN-20-M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipPiping thread type Optional specifications Cooling method Power Supply Specification

SGD 24,638.83

1 Piece(s) 32 Day(s) RcNone--

-

1 Piece(s) Quote RcWith earth leakage circuit breaker--

-

1 Piece(s) Quote RcWith earth leakage circuit breaker / With automatic water supply--

-

1 Piece(s) Quote RcWith earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote RcWith earth leakage circuit breaker / Compatible with deionized water (pure water) piping--

SGD 25,450.72

1 Piece(s) 32 Day(s) RcWith automatic water supply--

-

1 Piece(s) Quote RcWith automatic water supply / Compatible with deionized water (pure water) piping--

-

1 Piece(s) Quote RcCompatible with deionized water (pure water) piping--

-

1 Piece(s) Quote RcSI unit fixedWater-cooled refrigeration typeThree-phase 200 V AC (50 Hz) / Three-phase 200 to 230 V AC (60 Hz)

SGD 27,109.83

1 Piece(s) 32 Day(s) RcNoneWater-cooled refrigeration typeThree-phase 380 to 415 V AC (50/60 Hz)

-

1 Piece(s) Quote RcWith automatic water supplyWater-cooled refrigeration typeThree-phase 380 to 415 V AC (50/60 Hz)

SGD 31,981.13

1 Piece(s) 32 Day(s) RcWith automatic water supply / Compatible with deionized water (pure water) pipingWater-cooled refrigeration typeThree-phase 380 to 415 V AC (50/60 Hz)

SGD 31,169.25

1 Piece(s) 32 Day(s) RcCompatible with deionized water (pure water) pipingWater-cooled refrigeration typeThree-phase 380 to 415 V AC (50/60 Hz)

-

1 Piece(s) Quote G (Rc-G conversion fitting included)None--

-

1 Piece(s) Quote G (Rc-G conversion fitting included)With earth leakage circuit breaker--

-

1 Piece(s) Quote G (Rc-G conversion fitting included)With earth leakage circuit breaker / With automatic water supply--

-

1 Piece(s) Quote G (Rc-G conversion fitting included)With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) pipingWater-cooled refrigeration typeThree-phase 200 V AC (50 Hz) / Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote G (Rc-G conversion fitting included)NoneWater-cooled refrigeration typeThree-phase 380 to 415 V AC (50/60 Hz)

-

1 Piece(s) Quote NPT (Rc-NPT conversion fitting included)None--

-

1 Piece(s) Quote NPT (Rc-NPT conversion fitting included)With earth leakage circuit breaker--

-

1 Piece(s) Quote NPT (Rc-NPT conversion fitting included)With earth leakage circuit breaker / With automatic water supplyWater-cooled refrigeration typeThree-phase 200 V AC (50 Hz) / Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote NPT (Rc-NPT conversion fitting included)With earth leakage circuit breaker / with automatic water supply / SI unit onlyWater-cooled refrigeration typeThree-phase 200 V AC (50 Hz) / Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote NPT (Rc-NPT conversion fitting included)With earth leakage circuit breaker / Compatible with deionized water (pure water) pipingWater-cooled refrigeration typeThree-phase 200 V AC (50 Hz) / Three-phase 200 to 230 V AC (60 Hz)

-

1 Piece(s) Quote NPT (Rc-NPT conversion fitting included)Compatible with deionized water (pure water) pipingWater-cooled refrigeration typeThree-phase 200 V AC (50 Hz) / Three-phase 200 to 230 V AC (60 Hz)

Loading...

  1. 1

Basic Information

Cooling capacity 9 kW

Tech Support