Electronic Temperature Controller E5C2

Electronic Temperature Controller E5C2

[Features]
· The smallest type, available at low cost
· Proportional (P) motion is available in the adjustment mode. In addition, reset adjustment function has been added
· The mounting adapter enables continuous close-contact installation
· Plug-in method enables DIN rail mounting and panel embedding

PDF

Japanese Only

Drawing

Drawing of electronic temperature controller
Electronic temperature controller

Terminal arrangement

Product Specifications

Rating

Power supply voltage100 to 240 V AC 50/60 Hz
Allowable voltage fluctuation range90 to 110% of power supply voltage
Power ConsumptionApprox. 3.6 VA
InputThermocouple (with burnout circuit)
Platinum Resistance Thermometer
Element compatible thermistor
Control methodON/OFF operation, proportional operation (P)
Setting methodAnalog setting
Indication systemNo indications
Control OutputRelay output1c 250 V AC 3 A (resistant load)
(However, the opening and closing capacity is 330 V A)
Ambient operating temperature-10 to +55℃ (however, no freezing or no condensation)
Operating ambient humidityRelative humidity 45 to 85%

*. Do not use the output of the inverter as a power supply.

Performance

Setting accuracy±2% FS or less (effect of electromagnetic interference ±4% FS or less)
Adjustment sensitivity0.5% FS or less (fixed)
Proportional band3%FS (fixed)
Proportional periodApprox. 20 s
Reset range5±1%FS * 2
Insulation Resistance20 MΩ or more (at 500 V DC megger)
Withstand Voltage2,000 V AC 50/60 Hz for 1 min
(however, between the conductive terminal batch and the non-charged metal part)
VibrationMalfunction10 to 55 Hz Single amplitude 0.15 mm X, Y, Z 10 min in each direction
Durability16.7 Hz Single amplitude 2 mm X, Y, Z 2 h in each direction
ImpactMalfunction147 m/s^2, 6 directions, 3 times each
Durability294 m/s^2, 6 directions, 3 times each
LifeElectrical100,000 times or more (110 V AC 3 A resistant load)
WeightApprox. 100 g (With recessed mounting adapter)
Protective EnclosureIEC standard, front operation unit IP40, terminal unit IP00
Applicable socketType P2CF-08 (sold separately), type P3G-08 (Sold separately)
Applicable front coverShape Y92A-48B (Sold separately)

* 2. The ON/OFF operation type does not have a reset function.
       The reset function is used to correct the offset during proportional operation.
       If the offset occurs below the set value, turn the reset adjustment axis to the right (clockwise).

Part Number
E5C2-R20G AC100-240 0-100
E5C2-R20G AC100-240 50-150
E5C2-R20G AC100-240 150-300
E5C2-R20G AC100-240 -50-50
E5C2-R20K AC100-240 0-1000
E5C2-R20K AC100-240 0-200
E5C2-R20K AC100-240 0-300
E5C2-R20K AC100-240 0-400
E5C2-R20K AC100-240 0-600
E5C2-R20K AC100-240 0-800
E5C2-R20P-D AC100-240 0-50
E5C2-R20P-D AC100-240 0-100
E5C2-R20P-D AC100-240 0-200
E5C2-R20P-D AC100-240 0-300
E5C2-R20P-D AC100-240 0-400
E5C2-R20P-D AC100-240 -50-50
E5C2-R40K AC100-240 0-200
E5C2-R40K AC100-240 0-300
E5C2-R40K AC100-240 0-400
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipInput Method Control Method Number of Control Points Number of Input Points
(pcs.)
Control Output 1 Standard scale
(℃)

SGD 162.14

1 Piece(s) 7 Day(s) or more ThermistorON/OFF Control-1Relay0-100

SGD 157.30

1 Piece(s) 7 Day(s) or more ThermistorON/OFF Control-1Relay50-150

SGD 141.62

1 Piece(s) 11 Day(s) or more ThermistorON/OFF Control11Relay150-300

SGD 141.62

1 Piece(s) 11 Day(s) or more ThermistorON/OFF Control11Relay-50-50

SGD 157.80

1 Piece(s) 14 Day(s) or more ThermocoupleON/OFF Control11Relay0-1000

SGD 180.29

1 Piece(s) 4 Day(s) or more ThermocoupleON/OFF Control-1Relay0-200

SGD 160.45

1 Piece(s) 4 Day(s) or more ThermocoupleON/OFF Control-1Relay0-300

SGD 145.20

1 Piece(s) 7 Day(s) or more ThermocoupleON/OFF Control-1Relay0-400

SGD 171.82

1 Piece(s) 7 Day(s) or more ThermocoupleON/OFF Control-1Relay0-600

SGD 157.80

1 Piece(s) 7 Day(s) or more ThermocoupleON/OFF Control11Relay0-800

SGD 157.80

1 Piece(s) 22 Day(s) or more Platinum temperature measuring resistorON/OFF Control11Relay0-50

SGD 181.50

1 Piece(s) 7 Day(s) or more Platinum temperature measuring resistorON/OFF Control-1Relay0-100

SGD 169.40

1 Piece(s) 7 Day(s) or more Platinum temperature measuring resistorON/OFF Control-1Relay0-200

SGD 157.80

1 Piece(s) 14 Day(s) or more Platinum temperature measuring resistorON/OFF Control11Relay0-300

SGD 195.19

1 Piece(s) 14 Day(s) or more Platinum temperature measuring resistorON/OFF Control1--0-400

SGD 157.80

1 Piece(s) 11 Day(s) or more Platinum temperature measuring resistorON/OFF Control11Relay-50-50

SGD 157.80

1 Piece(s) 14 Day(s) or more ThermocoupleP Control11Relay0-200

SGD 160.93

1 Piece(s) 11 Day(s) or more ThermocoupleP Control-1Relay0-300

SGD 157.80

1 Piece(s) 8 Day(s) or more ThermocoupleP Control11Relay0-400

Loading...

  1. 1

Basic Information

Output Type Relay contact Failure Detecting Function No Power Supply Voltage(V) 100 to 240 VAC

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)