(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
An electric actuator with display setting functionality.
[Features]
・ Pulse input type motor driver
・ Supported motor capacity: 100 W, 200 W, 400 W
・ Compatible encoder: Incremental type, absolute type
・ Servo adjustment by auto gain tuning
Part Number
Configured Part Number is shown.
LECSB2-S5
Incremental type LECSA Series external appearance
Pulse input type / Positioning type
Absolute type LECSB Series external appearance
Pulse input type
Absolute type LECSC Series external appearance
CC-Link direct input type
Absolute type LECSS Series external appearance
SSCNETIII type
(Units: mm)
LECSA□ dimensional drawing (Left image: for LECSA□-S1, S3 / Center image: for LECSA□-S4)
LECSB□ dimensional drawing (Right image: 135 [for LECSB□-S5, S7], 170 [for LECSB□-S8])
*Battery included.
LECSC□ dimensional drawing (Right image: 135 [for LECSC□-S5, S7], 170 [for LECSC□-S8])
*Battery included.
LECSS□ dimensional drawing (Right image: 135 [for LECSS□-S5, S7], 170 [for LECSS□-S8])
*Battery included.
Model | LECSA1-S1 | LECSA1-S3 | LECSA2-S1 | LECSA2-S3 | LECSA2-S4 | |
---|---|---|---|---|---|---|
Compatible Motor Capacity [W] | 100 | 200 | 100 | 200 | 400 | |
Compatible Encoder | Incremental 17‑bit encoder (Resolution: 131,072 pulses/rotation) | |||||
Main Power Supply | Voltage [V] | Single phase 100 to 120 AC (50/60 Hz) | Single phase 200 to 230 AC (50/60 Hz) | |||
Allowable Voltage Fluctuation [V] | Single phase 85 to 132 AC | Single phase 170 to 253 AC | ||||
Rated Current [A] | 3.0 | 5.0 | 1.5 | 2.4 | 4.5 | |
Control Power Supply | Control Power Supply Voltage [V] | 24 V DC | ||||
Control Power Supply Allowable Voltage Fluctuation [V] | 21.6 to 26.4 DC | |||||
Rated Current [A] | 0.5 | |||||
Parallel Input | 6 inputs | |||||
Parallel Output | 4 points | |||||
Maximum Input Pulse Frequency [pps] | 1 M (for differential receiver), 200 k (for open collector) *2 | |||||
Function | In-position Range Setting [Pulse] | 0 to ±65,535 (command pulse unit) | ||||
Error Excess | ±3 rotations | |||||
Torque Limit | Parameter setting | |||||
Communication | USB communication | |||||
Operating Temperature Range [°C] | 0 to 55 (no freezing) | |||||
Operating Humidity Range [%RH] | 90 or less (no condensation) | |||||
Storage Temperature Range [°C] | −20 to 65 (no freezing) | |||||
Storage Humidity Range [%RH] | 90 or less (no condensation) | |||||
Insulation Resistance [MΩ] | Between the case and SG: 10 (500 V DC) | |||||
Weight [g] | 600 | 700 |
Model | LECSB1-S5 | LECSB1-S7 | LECSB2-S5 | LECSB2-S7 | LECSB2-S8 | |
---|---|---|---|---|---|---|
Compatible Motor Capacity [W] | 100 | 200 | 100 | 200 | 400 | |
Compatible Encoder | Absolute 18‑bit encoder (Resolution: 262,144 pulses/rotation) | |||||
Main Power Supply | Voltage [V] | Single phase 100 to 120 AC (50/60 Hz) | Three phase 200 to 230 AC (50/60 Hz), Single phase 200 to 230 AC (50/60 Hz) | |||
Allowable Voltage Fluctuation [V] | Single phase 85 to 132 AC | Three phase 170 to 253 AC, Single phase 170 to 253 AC | ||||
Rated Current [A] | 3.0 | 5.0 | 0.9 | 1.5 | 2.6 | |
Control Power Supply | Control Power Supply Voltage [V] | Single phase 100 to 120 AC (50/60 Hz) | Single phase 200 to 230 AC (50/60 Hz) | |||
Control Power Supply Allowable Voltage Fluctuation [V] | Single phase 85 to 132 AC | Single phase 170 to 253 AC | ||||
Rated Current [A] | 0.4 | 0.2 | ||||
Parallel Input | 10 points | |||||
Parallel Output | 6 inputs | |||||
Maximum Input Pulse Frequency [pps] | 1 M (for differential receiver), 200 k (for open collector) *2 | |||||
Function | In-position Range Setting [Pulse] | 0 to ±10,000 (command pulse unit) | ||||
Error Excess | ±3 rotations | |||||
Torque Limit | Parameter setting or external analog input setting (0 to 10 V DC) | |||||
Communication | USB communication, RS422 communication *1 | |||||
Operating Temperature Range [°C] | 0 to 55 (no freezing) | |||||
Operating Humidity Range [%RH] | 90 or less (no condensation) | |||||
Storage Temperature Range [°C] | −20 to 65 (no freezing) | |||||
Storage Humidity Range [%RH] | 90 or less (no condensation) | |||||
Insulation Resistance [MΩ] | Between the case and SG: 10 (500 V DC) | |||||
Weight [g] | 800 | 1,000 |
Item | LECSC1-S5 | LECSC1-S7 | LECSC2-S5 | LECSC2-S7 | LECSC2-S8 | ||
---|---|---|---|---|---|---|---|
Compatible Motor Capacity [W] | 100 | 200 | 100 | 200 | 400 | ||
Compatible Encoder | Absolute 18‑bit encoder (Resolution: 262,144 pulses/rotation) | ||||||
Main Power Supply | Voltage [V] | Single phase 100 to 120 AC (50/60 Hz) | Three phase 200 to 230 AC (50/60 Hz), Single phase 200 to 230 AC (50/60 Hz) | ||||
Allowable Voltage Fluctuation [V] | Single phase 85 to 132 AC | Three phase 170 to 253 AC, Single phase 170 to 253 AC | |||||
Rated Current [A] | 3.0 | 5.0 | 0.9 | 1.5 | 2.6 | ||
Control Power Supply | Control Power Supply Voltage [V] | Single phase 100 to 120 AC (50/60 Hz) | Single phase 200 to 230 AC (50/60 Hz) | ||||
Control Power Supply Allowable Voltage Fluctuation [V] | Single phase 85 to 132 AC | Single phase 170 to 253 AC | |||||
Rated Current [A] | 0.4 | 0.2 | |||||
Communication Specifications | Applicable Fieldbus Protocol (Version) | CC-Link communication (Ver. 1.10) | |||||
Connection Cable | CC-Link Ver. 1.10 compliant cable (shielded 3-core twisted-pair cable) *1 | ||||||
Remote Station Number | 1 to 64 | ||||||
Cable Length | Communication Speed [bps] | 16 k | 625 k | 2.5 M | 5 M | 10 M | |
Maximum Overall Cable Length [m] | 1,200 | 900 | 400 | 160 | 100 | ||
Cable Length Between Stations [m] | 0.2 or more | ||||||
Occupation Area (Inputs/Outputs) | 1 station occupied (remote I/O: 32 points / 32 points) / (remote register: 4 words / 4 words) 2 stations occupied (remote I/O: 64 points / 64 points) / (remote register: 8 words / 8 words) | ||||||
Number of Connectible Drivers | Up to 42 (when 1 station is occupied by 1 driver), or up to 32 (when 2 stations are occupied by 1 driver) with only remote device stations | ||||||
Command Method | Remote Register Input | Available with CC-Link communication (2 stations occupied) | |||||
Point Table No. Input | Available with CC-Link communication, RS-422 communication CC-Link communication (1 station occupied): 31 points, CC-Link communication (2 stations occupied): 255 points RS-422 communication: 255 points | ||||||
Indexer Positioning Input | Available with CC-Link communication CC-Link communication (1 station occupied): 31 points, CC-Link communication (2 stations occupied): 255 points | ||||||
Communication Function | USB communication, RS-422 communication *2 | ||||||
Operating Temperature Range [°C] | 0 to 55 (no freezing) | ||||||
Operating Humidity Range [%RH] | 90 or less (no condensation) | ||||||
Storage Temperature Range [°C] | -20 to 65 (No freezing) | ||||||
Storage Humidity Range [%RH] | 90 or less (no condensation) | ||||||
Insulation Resistance [MΩ] | Between the case and SG: 10 (500 V DC) | ||||||
Weight [g] | 800 | 1,000 |
Item | LECSS1-S5 | LECSS1-S7 | LECSS2-S5 | LECSS2-S7 | LECSS2-S8 | |
---|---|---|---|---|---|---|
Compatible Motor Capacity [W] | 100 | 200 | 100 | 200 | 400 | |
Compatible Encoder | Absolute 18‑bit encoder (Resolution: 262,144 pulses/rotation) | |||||
Main Power Supply | Voltage [V] | Single phase 100 to 120 AC (50/60 Hz) | Three phase 200 to 230 AC (50/60 Hz), Single phase 200 to 230 AC (50/60 Hz) | |||
Allowable Voltage Fluctuation [V] | Single phase 85 to 132 AC | Three phase 170 to 253 AC, Single phase 170 to 253 AC | ||||
Rated Current [A] | 3.0 | 5.0 | 0.9 | 1.5 | 2.6 | |
Control Power Supply | Control Power Supply Voltage [V] | Single phase 100 to 120 AC (50/60 Hz) | Single phase 200 to 230 AC (50/60 Hz) | |||
Control Power Supply Allowable Voltage Fluctuation [V] | Single phase 85 to 132 AC | Single phase 170 to 253 AC | ||||
Rated Current [A] | 0.4 | 0.2 | ||||
Applicable Fieldbus Protocol | SSCNET III (High-speed optical communication) | |||||
Communication Function | USB communication | |||||
Operating Temperature Range [°C] | 0 to 55 (no freezing) | |||||
Operating Humidity Range [%RH] | 90 or less (no condensation) | |||||
Storage Temperature Range [°C] | -20 to 65 (No freezing) | |||||
Storage Humidity Range [%RH] | 90 or less (no condensation) | |||||
Insulation Resistance [MΩ] | Between the case and SG: 10 (500 V DC) | |||||
Weight [g] | 800 | 1,000 |
LECSA□-□ power supply wiring example
LECSB1-□, LECSC1-□, LECSS1-□ power supply wiring example
Part Number |
---|
LECSB2-S5 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Input Power Supply | Position Detection | Motor type | Controller/driver type |
---|---|---|---|---|---|---|---|---|
SGD 1,348.32 | 1 Piece(s) | 32 Day(s) | AC Single-Phase, 200 ~ 230V | Absolute | AC servo motor (S6) | Pulse input type |
Loading...
Main Body, Peripheral Components | Peripheral Components |
---|
Please check the type/dimensions/specifications of the part LECSB2-S5 in the AC Servo Motor Driver, Incremental Type, LECSA Series / Absolute Type series.
Part Number |
---|
LECSA2-S3 |
LECSA2-S4 |
LECSB1-S5 |
LECSB2-S7 |
LECSB2-S8 |
LECSC2-S5 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Input Power Supply | Position Detection | Motor type | Controller/driver type |
---|---|---|---|---|---|---|---|---|
SGD 1,210.30 | 1 Piece(s) | 32 Day(s) | AC Single-Phase, 200 ~ 230V | Incremental | AC servo motor (S3) | Pulse input type / Positioning type | ||
SGD 1,259.18 | 1 Piece(s) | 32 Day(s) | AC Single-Phase, 200 ~ 230V | Incremental | AC servo motor (S4) | Pulse input type / Positioning type | ||
SGD 1,348.32 | 1 Piece(s) | 32 Day(s) | AC Single-phase 100 ~ 120V | Absolute | AC servo motor (S6) | Pulse input type | ||
SGD 1,471.98 | 1 Piece(s) | 32 Day(s) | AC Single-Phase, 200 ~ 230V | Absolute | AC servo motor (S7) | Pulse input type | ||
SGD 1,532.30 | 1 Piece(s) | 32 Day(s) | AC Single-Phase, 200 ~ 230V | Absolute | AC servo motor (S8) | Pulse input type | ||
SGD 1,880.20 | 1 Piece(s) | 32 Day(s) | AC Single-Phase, 200 ~ 230V | Absolute | AC servo motor (S6) | CC-Link direct input type |