Fluoropolymer Pipe Fitting, LQ2 Series, Male Branch Tee, Metric Size (LQ2B33-M)

Fluoropolymer Pipe Fitting, LQ2 Series, Male Branch Tee, Metric Size LQ2B33-M

Quadruple seal construction fluoropolymer fitting, male branch tee.
[Features]
· Material: New PFA.
· Maximum operating pressure (at 20°C): 1.0 MPa.
· Operating temperature: 0 to 200°C.
· The reducer method allows tubing size changes without replacing the body.

(i)Caution

  • For specifications and details, please refer to the catalog.
  • Product images may be representative images. Refer to the catalog for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

LQ2B33-M

Male Branch Tee LQ2B-M Metric Size Specifications

Male Branch Tee Dimensional Drawing

Male Branch Tee Dimensional Drawing

(A): Reference dimension after installation
(E): Reference dimension for the inserted tubing from the end surface of the nut

Male Branch Tee Dimensional Drawing for Sizes 2, 3

Male Branch Tee Dimensional Drawing for Sizes 2, 3

Male Branch Tee Dimensional Drawing for Sizes 4, 5

Male Branch Tee Dimensional Drawing for Sizes 4, 5

ModelApplicable Tubing Outer DiameterConnection thread
R/NPT
ABEFGHL1L2MN
LQ2B21-M□ø61/8 "18.5ø4196121834.52219.9-
LQ2B22-M□ø4
LQ2B23-M□ø61/4 "16.5
LQ2B24-M□ø4
LQ2B31-M□ø101/4 "23.5ø522918244329.526.2-
LQ2B32-M□ø8
LQ2B33-M□ø642.5
LQ2B34-M□ø103/8 "2343
LQ2B35-M□ø8
LQ2B36-M□ø642.5
LQ2B41-M□ø123/8 "30ø628112230523633.121
LQ2B42-M□ø1051
LQ2B43-M□ø121/2 "28.552
LQ2B44-M□ø1051
LQ2B51-M□ø191/2 "35ø73214283659.542.54026
LQ2B52-M□ø1258.5
LQ2B53-M□ø193/4 "33.559.5
LQ2B54-M□ø1258.5

Unit: mm

Withstand Pressure and Heat Resistance Performance

Withstand Pressure and Heat Resistance Performance Data

Withstand Pressure and Heat Resistance Performance Data

Applicable Fluids

ChemicalCompatibility
Acetic acid100%Acetic acid
Acetone100%Acetone○ Note)
Ammonium fluoride40%Ammonium fluoride
Ammonium hydroxide30%Ammonium hydroxide
Butyl acetate100%Butyl acetate
Methylene chloride100%Methylene chloride
Hydrochloric acid38%Hydrochloric acid
Hydrofluoric acid50%Hydrofluoric acid
Hydrogen peroxide60%Hydrogen peroxide
Methanol100%Methanol
Methyl ethyl Ketone-Methyl ethyl Ketone
Nitric acid70%Nitric acid
Phosphoric acid86%Phosphoric acid
Caustic potash85%Caustic potash
Sulfuric acid100%Sulfuric acid
Toluene-Toluene○ Note)
Xylene-Xylene
Sodium hydroxide100%Sodium hydroxide
1.1.1-Trichloroethane100%1.1.1-Trichloroethane
Phosphorus pentachloride-Phosphorus pentachloride
Isobutyl alcohol-Isobutyl alcohol○ Note)
Isopropyl alcohol-Isopropyl alcohol○ Note)
Ozone-Ozone
Ethyl acetate-Ethyl acetate○ Note)
Pure water-Pure water
Nitrogen-Nitrogen
Ultrapure water-Ultrapure water
Tmah-Tmah

○: Can be used
The material and fluid compatibility check list provides reference values as a guide only.
Note) Static electricity may be generated. Implement suitable countermeasures.

  • *Fluid temperature indicates compatibility below 200°C.
  • * The material and fluid compatibility check list provides reference values as a guide only, therefore we do not guarantee the application to our product.
  • * The data above is based on the information presented by the material manufacturers.
  • * The manufacturer is not responsible for the accuracy of the data and any damage incurred from the data.

Precautions for piping

1. Use special tools to connect tubing.

Special Tool Outline Drawing

Special Tool Outline Drawing

2. Tighten the nut until it touches the end surface of the body, and then tighten it an additional 1/8 turn to ensure that the nut has reached the end surface. If the nut will not turn any further, then it means a sufficient tightening has occurred. Refer to the proper tightening torques shown below.

Body sizeTorque (N·m)
21.5 to 2.0
33.0 to 3.5
47.5 to 9.0
511.0 to 13.0

*See the manufacturer's catalog for other precautions and important notes before use.

Part Number
LQ2B33-M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Type Applicable Tube Outer Dia. (mm) D (D1) Applicable Tube O.D. (mm) D2 Connection Screw Type M (M1) Connection Screw Nominal M (M1) Size of Body

SGD 109.20

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Equal Diameter)6-R1/4B(8A)3

Loading...

  1. 1

Basic Information

Type Fitting Body Material PFA Thread-to-Pipe Multipoint Connection Type Male Branch Tee
Maximum Operating Temperature(°C) 200

Please check the type/dimensions/specifications of the part LQ2B33-M in the Fluoropolymer Pipe Fitting, LQ2 Series, Male Branch Tee, Metric Size series.

Similar Part Numbers

Part Number
LQ2B2122-MN
LQ2B22-M
LQ2B22-MN
LQ2B33-MN
LQ2B3331-M
LQ2B3331-MN
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConnection Type Applicable Tube Outer Dia. (mm) D (D1) Applicable Tube O.D. (mm) D2 Connection Screw Type M (M1) Connection Screw Nominal M (M1) Size of Body

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)64NPT (Male thread)1/8B(6A)2

SGD 80.15

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Equal Diameter)4-R1/8B(6A)2

SGD 80.15

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Equal Diameter)4-NPT (Male thread)1/8B(6A)2

SGD 109.20

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Equal Diameter)6-NPT (Male thread)1/4B(8A)3

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)610R1/4B(8A)3

-

1 Piece(s) Quote [Thread <-> Tube, Branch] Thread-to-Pipe Branch (Reducing)610NPT (Male thread)1/4B(8A)3

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)