(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Multi-Core Straight Flat Tube for General Piping (UQ06-2F-100-B-B-L4)

Multi-Core Straight Flat Tube for General Piping UQ06-2F-100-B-B-L4
  • On Sale Till 31/03/2025

Flat tubes ideal for filling machine-related specifications.
[Features]
·Multiple pipes such as double-acting drive equipment can be neat and clean.
·UQ using flexible polyurethane tube and UCQ using ultra-soft polyurethane tube are available.
·In the case of black with 2 cores, an identification line is printed on one side of the tube to prevent piping mistakes.
·Cut marks are displayed at intervals of approx. 500 mm, which is useful when cutting the tube.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

UQ06-2F-100-B-B-L4

Specifications Of Multi-Core Straight Planar Tube For General Piping

Appearance of Multi-Core Straight Planar Tube For General Piping

Usable fluids: air
Maximum operating pressure (at 20°C 65% RH): 0.8 MPa *4
Operating vacuum pressure: -100 kPa
Operating temperature range: -15 to +60°C (no freezing)

Warning

  • *1. When using water, make sure the surge pressure stays below the maximum operating pressure.
  • *2. Tap water of the standard equivalent to the water supply in Japan can be used. Please inquire if you want to use other kinds of water.
  • *3. Be sure to use an insert ring when connecting to a one-touch fitting and using water.
  • *4. The maximum operating pressure is the value at 20°C 65% RH. When using the product at other temperatures, maintain a sufficient margin of safety from the burst pressure curve. Note that if the tube is in an area that is subject to shaking, bending, or other movement, intermolecular heat generation may raise the temperature of the tube and cause it to break.

Size Chart

FormatTube Outer Diameter
(ømm)
Tube Internal Diameter
(ømm)
Standard Overall Length
(m)
Number Of CoresWeight
(g/m)
UQ03-2F-(4)-(5)-(6)3220/100214
UQ04-2F-(4)-(5)-(6)42.520/100218
UQ06-2F-(4)-(5)-(6)6420/100238
UQ08-2F-(4)-(5)-(6)8520/100272
UQ10-2F-(4)-(5)-(6)106.520/1002108
UQ12-2F-(4)-(5)-(6)12820/1002148
  • *1. Input the tube overall length for (4) in the order format and the tube color for (5), (6), (7), (8), (9) and (10). We will also accept production orders for colors other than black.
  • *2. We will also accept production orders for tube lengths other than the above.
  • *3. Planar tubes with 3 or more cores (3 to 6 cores) can be made to order.

Compatible Sizes

Symbol030406081012
Outer Diameter (mm)ø3ø4ø6ø8ø10ø12
Internal Diameter (mm)ø2ø2.5ø4ø5ø6.5ø8

Burst pressure curve (reference value)

Burst pressure curve (reference value) chart

Burst pressure curve (reference value) chart

Precautions

Warning

  1. 1. Avoid stretching, twisting, over-bending, or otherwise straining the tubes. This may crush or rupture the tubes or cause them to come loose.
  2. 2. Avoid scraping the tubes by rubbing or entwining them. This may cause the tubes to rupture.
  3. 3. The tube burst pressure is a reference value calculated based on interaction with a hoop. Since the burst pressure decreases with increasing temperature, be sure to maintain a sufficient margin of safety based on a good understanding of the operating pressure in this documentation.
  4. 4. The minimum bending radius and the minimum mounting radius of the tube are the values at 20°C 65% RH and are not guaranteed values. When wrapping the tube around a mandrel (cylindrical rod), use the minimum bending radius value as a guide. Otherwise, use the minimum mounting radius value. In addition, since the values vary depending on the usage environment and tube length, it is important to adequately consider compatibility with the actual equipment to be used before deciding on a solution.
  5. 5. When connecting an extremely soft tube such as the Soft Polyurethane Tube (UC) or Vacuum Tube (UD) to a one-touch fitting and flowing water through it, be sure to use the insert ring (WR). Failure to use the insert ring may cause the tube to detach.
  6. 6. In places where spattering occurs, do not use any tube other than the Sputter Tube (FB). There is a risk that the spattering may cause a fire.
  7. 7. In areas requiring electrostatic dissipation and antistatic measures, do not use any tube other than the Antistatic Tube (UE). There is a risk that the system may fail or malfunction due to static electricity.
  8. 8. If there is an abnormal increase in temperature due to adiabatic compression, the tube might break.
  9. 9. Before using the product outdoors or otherwise deviating from the fluids, conditions, and environments described in the specifications, it is necessary to give adequate consideration to safety precautions as well as compatibility with the actual equipment to be used.

Cautions

  1. 1. Use a tube that meets or exceeds the minimum bending radius and minimum mounting radius.
  2. 2. When piping with tubes, be sure to allow enough room to accommodate changes in tube length and other future modifications.
  3. 3. When connecting a tube to a one-touch fitting, make sure that the tube has been cut at a right angle, that the outside of the tube is free of scratches, and that the tube does not form an ellipse.
  4. 4. Note that the effective area varies depending on the length of the tube piping. When installing long piping, refer to "Effective Area of Piping" under "Tube Performance."
Part Number
UQ06-2F-100-B-B-L4
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCutting Service Usage Outer Dia. D
(Ø)
O.D. [Distinction] Inner Dia. d
(Ø)
I.D. [Distinction] Minimum Bending Radius
(mm)
Operating Temperature Range (when using air)
(°C)
Operating Pressure Range (when using air)
(MPa)
Length M
(m)

SGD 36.33

1 Piece(s) 4 Day(s) or more Presence6~64~415-15~ 600~ 0.84

Loading...

  1. 1

Basic Information

Type Flat Material Urethane Applicable Fluid Air
Operating Environment Standard Color Black Number of Core(Core) 2
Material, Urethane Multi-core type polyurethane Operating Vacuum Level(kPa) -100

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)