NA2464 UL with Shield AWG28 (Part Numbers)

NA2464 UL with Shield AWG28

300 V cable, ULAWM2464 standard compliant. A small diameter type with a braided shield for EMI shielding.

  • VW-1
  • ULAWM
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • 300 V

● Braid-shielded for EMI countermeasures.

· Be careful not to confuse specified length and quantity when ordering.
· 1P = 2-core (twisted pair).
· Not oil-resistant.
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

NA2464-3P-9

Specifications

NA2464 UL with Shield AWG28:Related Image

Model NumberNumber of Pairs
1P = 2 Cores
Total Length
or
Specified Length
Sample
Provided
NA24642P1
~
100
(Specify 1 m
Increment)
3P
5P
8P
10P
13P
17P
20P
25P
30P
32P

More Information

Sheath ColorNavy
Operating Temperature Range0 ~ 80°C
Standard AcquiredULAWM2464
UL File No.E120411
Bending RadiusFinished Outer Diameter x 8 (Fixed Part Only)

Specifications
Model NumberAWG
Size
Number of Pairs
1P = 2 Cores
Specified Length
(m)
ConductorInsulation
Thickness
(mm)
Wire Core
Outer Diameter
Approx. (mm)
Sheath
Thickness
(mm)
Finished
Outer Diameter
(mm)
Electrical PropertiesApproximate
Mass
kg/km
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Test Voltage
V / Min
Allowable Current
A (30 °C)
NA2464AWG28
* (0.08 mm2)
2P1 ~ 100
(Specify 1 m Increment)
7/0.127
(Tin Plated)
0.380.331.040.86228 or less100 or more5001.950
3P0.86.31.654
5P0.87.42.3861
8P18.2276
10P18.91.8389
13P19.81.74106
17P1.110.91.55131
20P1.111.61.53145
25P1.312.71.44171
30P1.313.71.37197
32P1.314.11.34207
* Allowable current is to be used only as a reference value and is not guaranteed. * (~ mm2) is to be used only as a guide. Refer to the comparison table on >>Click here for details.
* Allowable current value for 2P and 3P is lower than that of 5P for manufacturing reasons. It is not a typographical error.
* For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

Structure Outline
ConductorTin Plated Annealed Copper Stranded Wire
InsulatorVinyl
TwistingTwisted Pair
ShieldTin Plated Annealed Copper Braid
SheathHeat-Resistant Vinyl / Matte

Current Reduction Factor
Ambient Temperature (°C)30 or less40506070
Current Reduction Factor1.000.890.770.630.45
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value. If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG28 5P when the ambient temperature is 40°C
2.38 x 0.89 = 2.11 (A)

Wire Core Identification Table
Pair No.Insulator
Color
Dot MarkDot Mark ColorPair No.Insulator
Color
Dot MarkDot Mark Color
Core of Wire 1Core of Wire 2Core of Wire 1Core of Wire 2
1OrangeBlackRed17Yellow■■■■BlackRed
2YellowBlackRed18Light Green■■■■BlackRed
3Light GreenBlackRed19Gray■■■■BlackRed
4GrayBlackRed20White■■■■BlackRed
5WhiteBlackRed21Orange■■■■■■ (Continuous)BlackRed
6Orange■■BlackRed22Yellow■■■■■■ (Continuous)BlackRed
7Yellow■■BlackRed23Light Green■■■■■■ (Continuous)BlackRed
8Light Green■■BlackRed24Gray■■■■■■ (Continuous)BlackRed
9Gray■■BlackRed25White■■■■■■ (Continuous)BlackRed
10White■■BlackRed26Orange■■ (Dash *)BlackRed
11Orange■■■BlackRed27Yellow■■ (Dash *)BlackRed
12Yellow■■■BlackRed28Light Green■■ (Dash *)BlackRed
13Light Green■■■BlackRed29Gray■■ (Dash *)BlackRed
14Gray■■■BlackRed30White■■ (Dash *)BlackRed
15White■■■BlackRed31Orange■■■■ (Dash *)BlackRed
16Orange■■■■BlackRed32Yellow■■■■ (Dash *)BlackRed
*From pair No. 26, the dot mark is slightly elongated (dash).
Part Number
NA2464-3P-9
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
Logarithm Finished outer diameter
(mm)
Other properties

SGD 28.01

1 Piece(s) 4 Day(s) or more 9-3P6.3-

Loading...

  1. 1

Basic Information

AWG size(AWG) 28 Rated Voltage 300V Shield Present
Representative Standard UL Sheath (outer coating) color Navy color Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal Dual use

Please check the type/dimensions/specifications of the part NA2464-3P-9 in the NA2464 UL with Shield AWG28 series.

Similar Part Numbers

Part Number
NA2464-10P-11
NA2464-10P-12
NA2464-10P-13
NA2464-3P-90
NA2464-3P-91
NA2464-3P-92
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
Logarithm Finished outer diameter
(mm)
Other properties

SGD 54.14

1 Piece(s) 4 Day(s) or more 110.0810P8.9Pliability / Noise Resistance

SGD 58.63

1 Piece(s) 4 Day(s) or more 120.0810P8.9Pliability / Noise Resistance

SGD 63.14

1 Piece(s) 4 Day(s) or more 130.0810P8.9Pliability / Noise Resistance

SGD 217.25

1 Piece(s) 4 Day(s) or more 90-3P6.3-

SGD 219.61

1 Piece(s) 4 Day(s) or more 91-3P6.3-

SGD 221.97

1 Piece(s) 4 Day(s) or more 92-3P6.3-

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)