Insulated Crimp Terminal, Closed End Connector【100 Pieces Per Package】

Insulated Crimp Terminal, Closed End Connector

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

Insulated Crimp Terminal, Closed End Connector【100 Pieces Per Package】
It is an equipment for wearing on the head of the stripped wire that is not use.
[Features]
• Compatible electric wire size (AWG): 22, 20, 18, 16, 14, 12 and 10
• Compatible electric wire size (mm²): 0.3, 0.5, 0.75, 1.25, 2.0, 3.0 and 5.5
• Representative Standard: JIS (JQ0608005), UL (E74917) and CSA (LR66230)
[Applications]
It is an equipment for wearing on the head of the stripped wire that is not use.

  • UL
  • CSA
  • JIS

● Most commonly used crimp closed-end connectors with insulation. Any number of wires can be bundled together and connected.
● JIS (JQ0608005), UL (E74917) and CSA (LR66230) have been acquired.


· Use a dedicated tool for crimping.
· As it is not waterproof, use only in places where it cannot come into contact with water.
· Available from 1 pack (100 pieces).

PDF

Japanese Only

Specifications

Insulated Crimp Terminal, Closed End Connector:Related Image
 

1 Pack100-piece Pack
 
ModelColor
CE-1Milky White
CE-2
CE-5
CE-8

 

More Information

Insulated Crimp Terminal, Closed End Connector:Related Image

External Dimensions Table and Specifications

ModelInsulation MaterialRated VoltageOperating Temperature RangeExternal Dimensions (Unit: mm)Weight
(g)
Compatible Tool
ABCDEFGH
CE-1Nylon300V-40°C
-
+105°C
2.47.00.55.06.520.09.50.80.627GOU-A
CE-23.07.15.67.89.30.808GOU / 7GOU-A
CE-54.08.10.87.39.423.010.50.91.468GOU / 7GOU-A
CE-85.09.51.09.010.428.011.82.578GOU



Electric Wire Combination Table
(How to Use the Table)
In the case of CE-1, for example, this means that for a single standard wire of 0.3 mm2, the possible combinations of wire size and number of wires are from 1 to 3 for 0.3 mm2, or from 1 to 2 for 0.5 mm2, or 1 for 0.75 mm2.
ModelWire Conjugation RangeReference Wire SizeWire Size mm2 (AWG) and Possible Bundle Number
mm2mm2 (AWG)Count0.3 (22)0.5 (20)0.75 (18)1.25 (16)2.0 (14)3.5 (12)5.5 (10) Stranded Wire
CE-10.5-1.250.3 (22)11-31-211---
21-211----
3-11----
0.5 (20)11-3------
21-2------
0.75 (18)11-211----
1.25 (16)111-----
CE-21.0-3.00.3 (22)13-72-41-21-21--
2-1-31-211--
3-1-31-211--
0.5 (20)12-61-41-21-21--
21-5-1-211--
31-4-1-21---
0.75 (18)11-51-31-211--
21-41-211---
31-21-----
1.25 (16)11-41-21-21---
2.0 (14)11-211----
CE-52.5-6.00.3 (22)17-95-93-62-3211
2-4-83-62-311-
3-4-73-5211-
0.5 (20)17-84-73-52-31-211
25-7-2-41-21-21-
33-5-2-31-21-21-
0.75 (18)16-84-72-42-31-21-
24-61-5-1-21-21-
31-51-3-1-211-
1.25 (16)15-83-42-41-21-21-
21-61-31-2-1--
31-51-21-2----
2.0 (14)12-71-41-41-21-21-
3.5 (12)11-61-41-211--
CE-84.0-9.00.5 (20)1-7-125-83-42-31-21
2--4-72-42-31-21
3--4-72-4211
4--3-61-31-211
5--2-51-31-211
6--2-41-2111
0.75 (18)1-7-115-83-42-31-21
2-5-10-2-421-21
3-4-9-2-31-211
4-2-8-1-21-211
5-1-6-1-211-
1.25 (16)1-7-114-83-4211
2-5-102-6-1-21-
3-1-71-4-1-21-
4-1-61-3-1-21-
2.0 (14)1-7-103-72-41-211
2-1-81-41-2-1-
3-1-51-21-2---
3.5 (12)1-1-81-51-2111
2-1-21-211--
5.5 (10) Stranded Wire1-1-51-41-311-

 

Part Number
CE-1
CE-2
CE-5
Part NumberStandard Unit PriceNumber of pc(s). included in pkg.Minimum order quantityVolume DiscountDays to ShipRoHSInternal Diameter
(φ)
Outer Diameter
(mm)
Overall Length
(mm)
Conforming wire size
(AWG)
Wire conjugation range
(mm2)
Terminal type classification

SGD 10.07

100 Pieces Per Package

1 Pack(s)Available Same day 102.452022-160.5 ~ 1.25M Model

SGD 10.52

100 Pieces Per Package

1 Pack(s)Available Same day 1035.62022-141.0 ~ 3.0F Model

SGD 15.59

100 Pieces Per Package

1 Pack(s)Available Same day 1047.32322-122.5 ~ 6.0M Model

Loading...

  1. 1

Features

● Crimp terminals are wire connection components that are used in a wide range of applications such as electrical engineering as well as domestic electrical appliances, measuring devices, FA control devices etc.
● Available in 2 types: conventional type bare crimp terminals without insulation sheathing, and crimp terminals with insulation sleeves.
● We also offer products with JIS, UL and CSA certification, allowing for use with peace of mind.

Allowable Current

Wire Size Used Terminal
Nominal Number
Allowable current or less (at 30°C)
Single Wire Stranded Wire AWG With rubber vinyl insulated wire Cord
Single Wire Stranded Wire
- 0.08 28 0.08 - - -
- 0.3 26, 24 0.3 - - -
0.8 0.3, 0.5 22, 20 0.5 - - -
1.0, 1.2 0.75, 0.9, 1.25 18, 16 1.25 16 A, 19 A 16 A, 17 A, 19 A 7 A (0.75 mm), 12 A
1.6 2 14 2 27 A 27 A 17 A
2.0 3.5 12 3.5 35 A 37 A 23 A
2.6 5.5 10 5.5 48 A 48 A 35 A
3.2 8 8 8 62 A 62 A -

Allowable Voltage

Bare Crimp Terminal: 600 VAC or less
Insulated Crimp Terminal: 300 VAC or less

Materials

Conductor Component: Oxygen-free Copper (Tin-Plated)
Insulator Component: Refer to product pages

Compatible Wire Size

Refer to product pages.

Crimping Method

Crimping Method

Diagram A

Diagram A
Terminal Nominal
(Note 3)
Wire Size Used Wire Sheath Strip Dimensions (mm)
Stranded Wire (mm2) Single Wire
(Dia. mm)
Wire Conjugation Capacity
(Note 1)
L
(Note 2)
L1 L2
0.08 0.08 - - B + L1 + L2 0.5 ~ 2 0 ~ 1
1.25 0.3, 0.5, 0.75,
0.9, 1.25
0.75 ~ 1.44 0.25 ~ 1.65 B + L1 + L2 0.5 ~ 2 0 ~ 1
2 1.25, 2.0 1.14 ~ 1.82 1.04 ~ 2.63 B + L1 + L2 0.5 ~ 2 0 ~ 1
5.5 3.5, 5.5 1.82 ~ 2.89 2.63 ~ 6.64 B + L1 + L2 0.5 ~ 2 0 ~ 1
8 8 2.89 ~ 3.65 6.64 ~ 10.52 B + L1 + L2 1 ~ 2 0 ~ 2
(Note 1) When 2 or more wires are inserted into terminals for crimping, ensure that the combined total of the wires' cross-sectional area is within the wire conjugation capacity range and is also similar to the terminal nominal.
(Note 2) The calculation method of the L dimension is simply for finding the dimensions of the wire sheath stripping, and is not used to indicate the shape or dimensions after crimping.
(Note 3) For applicable wires at 0.3, use a conductor cross-sectional area close to the terminal nominal. Furthermore, fold back the core wire when crimping thin types such as AWG28.
Also, ensure that the wire stripping dimension complies with the terminal nominal 1.25.

Crimping Guideline

Selection of Crimping Tool

Visual Inspection after Crimping

Basic Information

Type Crimp terminal with insulation Shape Enclosed type Insulation material Nylon
Representative Standard UL / JIS / CSA Notes Please refer to the catalog for details such as terminal shape and terminal Model.

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)