(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.
A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
A harness with an NR connector from NANABOSHI ELECTRIC MFG CO., LTD. Contributes to reducing labor-hours in wiring work on site by adopting a single-action lock. The robust product with a single-action lock system is easy to work with
Part Number
Configured Part Number is shown.
Specified Length (m) | ~ 0.9 | 1 ~ 4 | 4.1 ~ 50 |
Tolerance | +20mm | +50mm | + 3% of Specified Length |
Connector Type | Shape Specification Type | Outline Image Drawing (Unit: mm) | Shell Size | Number of Cores | Cable Type | Specified Length (m) |
One-End Straight Connector Type | ||||||
CNR Nanaboshi Electric Mfg.Co,Ltd. | PF (Female / Cut Off) PM (Male / Cut Off) ADF (Female Relay / Cut Off) ADM (Male Relay / Cut Off) | 20 | 2 | 0.2 ~ 50 Can be specified by 0.1m increments | ||
3 | ||||||
4 | ||||||
5 | ||||||
7 | ||||||
12 | ||||||
24 | 4 | |||||
10 | ||||||
16 | ||||||
PFT (Female / Mark Tube) PMT (Male / Mark Tube) ADFT (Female Relay / Mark Tube) ADMT (Male Relay / Mark Tube) | 20 | 2 | ||||
3 | ||||||
4 | ||||||
5 | ||||||
7 | ||||||
12 | ||||||
24 | 4 | |||||
10 | ||||||
16 | ||||||
RF (Female Panel Mount / Cut Off) RM (Male Panel Mount / Cut Off) RFT (Female Panel Mount / Mark Tube) RMT (Male Panel Mount / Mark Tube) | 20 | 2 | ||||
3 | ||||||
4 | ||||||
5 | ||||||
7 | ||||||
12 | ||||||
24 | 4 | |||||
10 | ||||||
16 |
Connector Type | Shape Specification Type | Outline Image Drawing (Unit: mm) | Shell Size | Number of Cores | Cable Type | Specified Length (m) |
Double-ended Straight Connector Type | ||||||
CNR Nanaboshi Electric Mfg.Co,Ltd. | PFPF (Female / Female) PFPM (Female / Male) PMPM (Male / Male) | 20 | 2 | 0.2 ~ 50 Can be specified by 0.1m increments | ||
3 | ||||||
4 | ||||||
5 | ||||||
7 | ||||||
12 | ||||||
24 | 4 | |||||
10 | ||||||
16 | ||||||
Relay Connector Type | ||||||
ADFPF (Female Relay / Female) ADFPM (Female Relay / Male) ADMPF (Male Relay / Female) ADMPM (Male Relay / Male) | 20 | 2 | ||||
3 | ||||||
4 | ||||||
5 | ||||||
7 | ||||||
12 | ||||||
24 | 4 | |||||
10 | ||||||
16 |
Connector Type (Shell Size - Number of Cores) | Connector | A Cable | B Cable | C Cable | D Cable | |||||||||
Rated Current (A or less) | Rated Voltage (V or less) | Section Area | Rated Voltage | Allowable Current A (30°C) | Section Area | Rated Voltage | Allowable Current A (30°C) | Section Area | Rated Voltage | Allowable Current A (30°C) | Section Area | Rated Voltage | Allowable Current A (30°C) | |
20-2 | 15 | 250 | 2.0mm2 (AWG14) | 300V | 17 | AWG21 (0.5 mm2) | 150V | 8.8 | AWG21 (0.5 mm2) | 150V | 9.6 | AWG14 (2.0 mm2) | 300V | 23 |
20-3 | 6.8 | 7.4 | 19 | |||||||||||
20-4 | 10 | 1.25mm2 (AWG16) | 12 | AWG16 (1.25mm2) | 12 | |||||||||
20-5 | 8 | 5.7 | 6.3 | 9 | ||||||||||
20-7 | 7 | 5 | 5.5 | 8 | ||||||||||
20-12 | 5 | 0.5mm2 (AWG20) | 3 | 3.9 | 4.3 | AWG20 (0.5mm2) | 3 | |||||||
24-4 | 15 | 2.0mm2 (AWG14) | 17 | 6.8 | 7.4 | AWG14 (2.0 mm2) | 16 | |||||||
24-10 | 10 | 1.25mm2 (AWG16) | 6 | 4.7 | 5.1 | AWG16 (1.25mm2) | 7 | |||||||
24-16 | 5 | 0.5mm2 (AWG20) | 3 | 3.5 | 3.8 | AWG20 (0.5mm2) | 3 |
Part Number |
---|
CNR-ADFPM-20-2-A-[0.2-50/0.1] |
CNR-ADFPM-20-2-B-[0.2-50/0.1] |
CNR-ADFPM-20-2-C-[0.2-50/0.1] |
CNR-ADFPM-20-2-D-[0.2-50/0.1] |
CNR-ADFPM-20-3-A-[0.2-50/0.1] |
CNR-ADFPM-20-3-B-[0.2-50/0.1] |
CNR-ADFPM-20-3-C-[0.2-50/0.1] |
CNR-ADFPM-20-3-D-[0.2-50/0.1] |
CNR-ADFPM-20-4-A-[0.2-50/0.1] |
CNR-ADFPM-20-4-B-[0.2-50/0.1] |
CNR-ADFPM-20-4-C-[0.2-50/0.1] |
CNR-ADFPM-20-4-D-[0.2-50/0.1] |
CNR-ADFPM-20-5-A-[0.2-50/0.1] |
CNR-ADFPM-20-5-B-[0.2-50/0.1] |
CNR-ADFPM-20-5-C-[0.2-50/0.1] |
CNR-ADFPM-20-5-D-[0.2-50/0.1] |
CNR-ADFPM-20-7-A-[0.2-50/0.1] |
CNR-ADFPM-20-7-B-[0.2-50/0.1] |
CNR-ADFPM-20-7-C-[0.2-50/0.1] |
CNR-ADFPM-20-7-D-[0.2-50/0.1] |
CNR-ADFPM-20-12-A-[0.2-50/0.1] |
CNR-ADFPM-20-12-B-[0.2-50/0.1] |
CNR-ADFPM-20-12-C-[0.2-50/0.1] |
CNR-ADFPM-20-12-D-[0.2-50/0.1] |
CNR-ADFPM-24-4-A-[0.2-50/0.1] |
CNR-ADFPM-24-4-B-[0.2-50/0.1] |
CNR-ADFPM-24-4-C-[0.2-50/0.1] |
CNR-ADFPM-24-4-D-[0.2-50/0.1] |
CNR-ADFPM-24-10-A-[0.2-50/0.1] |
CNR-ADFPM-24-10-B-[0.2-50/0.1] |
CNR-ADFPM-24-10-C-[0.2-50/0.1] |
CNR-ADFPM-24-10-D-[0.2-50/0.1] |
CNR-ADFPM-24-16-A-[0.2-50/0.1] |
CNR-ADFPM-24-16-B-[0.2-50/0.1] |
CNR-ADFPM-24-16-C-[0.2-50/0.1] |
CNR-ADFPM-24-16-D-[0.2-50/0.1] |
CNR-ADMPM-20-2-A-[0.2-50/0.1] |
CNR-ADMPM-20-2-B-[0.2-50/0.1] |
CNR-ADMPM-20-2-C-[0.2-50/0.1] |
CNR-ADMPM-20-2-D-[0.2-50/0.1] |
CNR-ADMPM-20-3-A-[0.2-50/0.1] |
CNR-ADMPM-20-3-B-[0.2-50/0.1] |
CNR-ADMPM-20-3-C-[0.2-50/0.1] |
CNR-ADMPM-20-3-D-[0.2-50/0.1] |
CNR-ADMPM-20-4-A-[0.2-50/0.1] |
CNR-ADMPM-20-4-B-[0.2-50/0.1] |
CNR-ADMPM-20-4-C-[0.2-50/0.1] |
CNR-ADMPM-20-4-D-[0.2-50/0.1] |
CNR-ADMPM-20-5-A-[0.2-50/0.1] |
CNR-ADMPM-20-5-B-[0.2-50/0.1] |
CNR-ADMPM-20-5-C-[0.2-50/0.1] |
CNR-ADMPM-20-5-D-[0.2-50/0.1] |
CNR-ADMPM-20-7-A-[0.2-50/0.1] |
CNR-ADMPM-20-7-B-[0.2-50/0.1] |
CNR-ADMPM-20-7-C-[0.2-50/0.1] |
CNR-ADMPM-20-7-D-[0.2-50/0.1] |
CNR-ADMPM-20-12-A-[0.2-50/0.1] |
CNR-ADMPM-20-12-B-[0.2-50/0.1] |
CNR-ADMPM-20-12-C-[0.2-50/0.1] |
CNR-ADMPM-20-12-D-[0.2-50/0.1] |
CNR-ADMPM-24-4-A-[0.2-50/0.1] |
CNR-ADMPM-24-4-B-[0.2-50/0.1] |
CNR-ADMPM-24-4-C-[0.2-50/0.1] |
CNR-ADMPM-24-4-D-[0.2-50/0.1] |
CNR-ADMPM-24-10-A-[0.2-50/0.1] |
CNR-ADMPM-24-10-B-[0.2-50/0.1] |
CNR-ADMPM-24-10-C-[0.2-50/0.1] |
CNR-ADMPM-24-10-D-[0.2-50/0.1] |
CNR-ADMPM-24-16-A-[0.2-50/0.1] |
CNR-ADMPM-24-16-B-[0.2-50/0.1] |
CNR-ADMPM-24-16-C-[0.2-50/0.1] |
CNR-ADMPM-24-16-D-[0.2-50/0.1] |
CNR-PFPM-20-2-A-[0.2-50/0.1] |
CNR-PFPM-20-2-B-[0.2-50/0.1] |
CNR-PFPM-20-2-C-[0.2-50/0.1] |
CNR-PFPM-20-2-D-[0.2-50/0.1] |
CNR-PFPM-20-3-A-[0.2-50/0.1] |
CNR-PFPM-20-3-B-[0.2-50/0.1] |
CNR-PFPM-20-3-C-[0.2-50/0.1] |
CNR-PFPM-20-3-D-[0.2-50/0.1] |
CNR-PFPM-20-4-A-[0.2-50/0.1] |
CNR-PFPM-20-4-B-[0.2-50/0.1] |
CNR-PFPM-20-4-C-[0.2-50/0.1] |
CNR-PFPM-20-4-D-[0.2-50/0.1] |
CNR-PFPM-20-5-A-[0.2-50/0.1] |
CNR-PFPM-20-5-B-[0.2-50/0.1] |
CNR-PFPM-20-5-C-[0.2-50/0.1] |
CNR-PFPM-20-5-D-[0.2-50/0.1] |
CNR-PFPM-20-7-A-[0.2-50/0.1] |
CNR-PFPM-20-7-B-[0.2-50/0.1] |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | CN1 | CN2 | Number Of Cores | Cable rated voltage (V) | Shell size | Shield | Cable standard (UL/CSA) | Cable color | Twisted pair | Conductor dimensions (AWG) | Environment resistant | Bend tolerant | Cable type | Specified Length (M) | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [2] 2 | 300 | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [2] 2 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [2] 2 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [2] 2 | 300 | 20 | N/A | UL | Navy | N/A | 14 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [3] 3 | 300 | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [3] 3 | 150 | 20 | 1 Layer | UL | Navy | N/A | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [3] 3 | 150 | 20 | 1 Layer | UL | Navy | N/A | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [3] 3 | 300 | 20 | N/A | UL | Navy | N/A | 14 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 300 | 20 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [5] 5 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [5] 5 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [5] 5 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [5] 5 | 300 | 20 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [7] 7 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [7] 7 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [7] 7 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [7] 7 | 300 | 20 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 12 | Less than 100 | 20 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 12 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 12 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 12 | 300 | 20 | N/A | UL | Navy | N/A | 20 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 300 | 24 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 300 | 24 | N/A | UL | Navy | N/A | 14 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 10 | 300 | 24 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 10 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 10 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 10 | 300 | 24 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [16] 16 | Less than 100 | 24 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [16] 16 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [16] 16 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [16] 16 | 300 | 24 | N/A | UL | Navy | N/A | 20 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [2] 2 | 300 | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [2] 2 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [2] 2 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [2] 2 | 300 | 20 | N/A | UL | Navy | N/A | 14 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [3] 3 | 300 | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [3] 3 | 150 | 20 | 1 Layer | UL | Navy | N/A | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [3] 3 | 150 | 20 | 1 Layer | UL | Navy | N/A | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [3] 3 | 300 | 20 | N/A | UL | Navy | N/A | 14 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 300 | 20 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [5] 5 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [5] 5 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [5] 5 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [5] 5 | 300 | 20 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [7] 7 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [7] 7 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [7] 7 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [7] 7 | 300 | 20 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 12 | Less than 100 | 20 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 12 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 12 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 12 | 300 | 20 | N/A | UL | Navy | N/A | 20 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 300 | 24 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 300 | 24 | N/A | UL | Navy | N/A | 14 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 10 | 300 | 24 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 10 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 10 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 10 | 300 | 24 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [16] 16 | Less than 100 | 24 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [16] 16 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [16] 16 | 150 | 24 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [16] 16 | 300 | 24 | N/A | UL | Navy | N/A | 20 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [2] 2 | 300 | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [2] 2 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [2] 2 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [2] 2 | 300 | 20 | N/A | UL | Navy | N/A | 14 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [3] 3 | 300 | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [3] 3 | 150 | 20 | 1 Layer | UL | Navy | N/A | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [3] 3 | 150 | 20 | 1 Layer | UL | Navy | N/A | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [3] 3 | 300 | 20 | N/A | UL | Navy | N/A | 14 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 4 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 4 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 4 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 4 | 300 | 20 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | C | 0.2 ~ 50 | Cable for Mobile Signals | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 300 | 20 | N/A | UL | Navy | N/A | 16 | Oil-resistant | Bending / Flexible | D | 0.2 ~ 50 | Cable for Mobile Power Sources | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [7] 7 | 300 | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | Generic Cable | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [7] 7 | 150 | 20 | 1 Layer | UL | Navy | Included | 21 | Oil-resistant | Bending / Flexible | B | 0.2 ~ 50 | Standard Cable for Signals |
Loading...
Common Specifications
Materials / Finish
Item | Materials | Finish |
---|---|---|
Shell / Dustproof Cap | Zinc Alloy | Satin Chrome-plated |
Aluminum Alloy (Shell Size 28 ) | ||
Insulator | Synthetic Resin | - |
Contact | Copper Alloy | Silver Plating |
Characteristics
Item | Characteristics | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rated Current | See table below | |||||||||||||
Rated Voltage | See table below | |||||||||||||
Withstand Voltage | No abnormality such as short circuiting occurs when regulated voltage is applied for 1 minute between immediately adjacent conductors. | |||||||||||||
Insulation Resistance | 1,000 MΩ or higher when measured between immediately adjacent conductors with regulated voltage. | |||||||||||||
Contact Resistance | Conductor resistance is 5 mΩ or less when a pair of contacts are connected at up to the regulation length. | |||||||||||||
Vibration Resistance | No functional defect was found during the JIS C 5025 vibration test. Contact resistance is 5 mΩ or less. | |||||||||||||
Impact Resistance | No functional defect was found during the JIS C 5026 shock test. Contact resistance is 5 mΩ or less. | |||||||||||||
Repeated Operation | No functional defect was found when a removal and insertion sequence was tested 500 times. Contact resistance is 5 mΩ or less. | |||||||||||||
Humidity Resistance | No functional defect was found during the JIS C 5023 humidity test. Insulation resistance is 100 MΩ or higher. | |||||||||||||
Temperature Cycle | No functional defect was found during the JIS C 5030 temperature cycle test. | |||||||||||||
Corrosion Resistance | No functional defect was found during the JIS C 5028 salt water spray test. Contact resistance is 5 mΩ or less. | |||||||||||||
Allowable Operating Temperature Range |
|
Product No. | Shell Size |
Number of Cores | Shape Symbol | Rated Current (A or less) |
Rated Voltage (V or less) |
Withstand Voltage AC (V) |
Insulation Resistance (MΩ or higher) |
Contact Resistance (mΩ or less) |
Compatible Wire Size | Applicable Electric Wire Finished Outer Diameter (mm) |
|
---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Conductor Section Area mm2 | ||||||||||
NR | 20 | 2, 3 | PF, RM, ADM |
15 | 250 | 1,500 | 2,000 | 3 | 14 | 2 | 10.0 ~ 12.5 |
4, 5 | 10 | 16 | 1.25 | ||||||||
7 | 1,000 | ||||||||||
12 | 5 | 1,000 | 5 | 20 | 0.5 | ||||||
20 | 2, 3 | PM, RF, ADF |
15 | 250 | 1,500 | 2,000 | 3 | 14 | 2 | 10.0 ~ 12.5 | |
4, 5 | 10 | 16 | 1.25 | ||||||||
7 | 1,000 | ||||||||||
12 | 5 | 1,000 | 5 | 20 | 0.5 | ||||||
24 | 2, 3 | PF, RM, ADM |
20 | 250 | 1,500 | 5,000 | 3 | 12 | 3.5 | 11.5 ~ 14.0 | |
4, 5 | 15 | 14 | 2 | ||||||||
10 | 10 | 1,000 | 2,000 | 16 | 1.25 | ||||||
14, 16 | 5 | 1,000 | 5 | 20 | 0.5 | ||||||
24 | 2, 3 | PM, RF, ADF |
20 | 250 | 1,500 | 5,000 | 3 | 12 | 3.5 | 11.5 ~ 14.0 | |
4, 5 | 15 | 14 | 2 | ||||||||
10 | 10 | 1,000 | 2,000 | 16 | 1.25 | ||||||
14, 16 | 5 | 1,000 | 5 | 20 | 0.5 |
Contact Arrangement Diagram
One-Touch Medium Type Metal (NR)
Features
Connection Work Method
Connector type | NR | Connector manufacturer | Nanaboshi Electric Mfg. Co., Ltd. | Cable shape | Circular |
---|
How can we improve?
How can we improve?