A wide variety of standard and configurable components for factory automation engineers in industries such as automotive, semiconductor, packaging, medical and many more.
A good selection of accessories such as screws, bolts, washers and nuts that you may need for your daily engineering usage.
Browse industrial materials ranging from heat insulating plates, sponges, to metal and plastic materials in different sizes to meet your various applications.
A wide variety of wiring parts for connecting and protecting control and PC parts including Connectors, Cables, Electric Wires, Crimping Terminals and more.
A wide variety of controls and PC parts for electrical engineers including Controls, Powers, PC parts and more.
A wide variety of cutting tools for many uses and work materials including End Mills, Drills, Cutters, Reamers, Turning Tools and more.
A wide variety of tools and supplies used in processing including Machine Tools, Measurement Tools, Grinding and Polishing Supplies and more.
A wide variety of goods used in shipment, material handling and warehouse including Tape supplies, Stretch film, Truck, Shelf, Crane and more.
A large variety of goods for every kind of factories and offices including Protection items, Cleaning supplies, sanitations, office supplies and more.
A large variety of items used in R&D and Clean Room including research Equipment, Laboratory Essentials, Analysis Supplies, Clean Environment-Related Equipment and more.
Choose from thousands of standard stamping die components including Punch & Die, Gas Springs, Guide Components, Coil Springs and many more.
Browse our wide variety of mold components including Ejector Pins, Sleeves, Leader Components, Sprue Bushings and many more.
Browse our injection molding components including Heating Items, Couplers, Hoses and more.
A harness with an NJC connector from NANABOSHI ELECTRIC MFG. Co., LTD. Lightweight and strong specifications for a wide range of applications including power supply and signaling, etc.
Part Number
Configured Part Number is shown.
Specified Length (m) | ~ 0.9 | 1 ~ 4 | 4.1 ~ 50 |
Tolerance | +20 mm | +50 mm | + 3% of Specified Length |
Connector Type | Shape Specification Type | Outline Image Drawing (Unit: mm) | Shell Size | Number of Cores (Cable Electric Wire Size) | Cable Type | Specified Length (m) |
RNJC (NJC Series) Nanaboshi Electric Mfg.Co,Ltd. | PF (Female / Cut Off) PM (Male / Cut Off) RF (Female Panel Mount / Cut Off) RM (Male Panel Mount / Cut Off) ADF (Female Relay / Cut Off) ADM (Male Relay / Cut Off) | 16 | 3 (1.25 mm2) | 0.2 ~ 50 Can be specified by 0.1m increments | ||
5 (0.5 mm2) | ||||||
20 | 3 (2 mm2) | |||||
4 (1.25 mm2) | ||||||
5 (1.25 mm2) | ||||||
7 (1.25 mm2) | ||||||
12 (0.5 mm2) | ||||||
24 | 4 (2 mm2) | |||||
5 (2 mm2) | ||||||
10 (1.25 mm2) | ||||||
14 (0.5 mm2) | ||||||
16 (0.5 mm2) | ||||||
28 | 16 (1.25 mm2) | |||||
24 (0.5 mm2) | ||||||
PFT (Female / Pin No. Insertion Mark Tube) PMT (Male / Pin No. Insertion Mark Tube) RFT (Female Panel Mount / Pin No. Insertion Mark Tube) RMT (Male Panel Mount / Pin No. Insertion Mark Tube) ADFT (Female Relay / Pin No. Insertion Mark Tube) ADMT (Male Relay / Pin No. Insertion Mark Tube) | 16 | 3 (1.25 mm2) | ||||
5 (0.5 mm2) | ||||||
20 | 3 (2 mm2) | |||||
4 (1.25 mm2) | ||||||
5 (1.25 mm2) | ||||||
7 (1.25 mm2) | ||||||
12 (0.5 mm2) | ||||||
24 | 4 (2 mm2) | |||||
5 (2 mm2) | ||||||
10 (1.25 mm2) | ||||||
14 (0.5 mm2) | ||||||
16 (0.5 mm2) | ||||||
28 | 16 (1.25 mm2) | |||||
24 (0.5 mm2) | ||||||
PFY (Female / Y Terminal) PMY (Male / Y Terminal) RFY (Female Panel Mount / Y Terminal) RMY (Male Panel Mount / Y Terminal) ADFY (Female Relay / Y Terminal) ADMY (Male Relay / Y Terminal) | 16 | 3 (1.25 mm2) | ||||
5 (0.5 mm2) | ||||||
20 | 3 (2 mm2) | |||||
4 (1.25 mm2) | ||||||
5 (1.25 mm2) | ||||||
7 (1.25 mm2) | ||||||
12 (0.5 mm2) | ||||||
24 | 4 (2 mm2) | |||||
5 (2 mm2) | ||||||
10 (1.25 mm2) | ||||||
14 (0.5 mm2) | ||||||
16 (0.5 mm2) | ||||||
28 | 16 (1.25 mm2) | |||||
24 (0.5 mm2) |
Connector Type | Shape Specification Type | Outline Image Drawing (Unit: mm) | Shell Size | Number of Cores (Cable Electric Wire Size) | Cable Type | Specified Length (m) |
RNJC (NJC Series) Nanaboshi Electric Mfg.Co,Ltd. | PFR (Female / Round Terminal) PMR (Male / Round Terminal) RFR (Female Panel Mount / Round Terminal) RMR (Male Panel Mount / Round Terminal) ADFR (Female Relay / Round Terminal) ADMR (Male Relay / Round Terminal) | 16 | 3 (1.25 mm2) | 0.2 ~ 50 Can be specified by 0.1m increments | ||
5 (0.5 mm2) | ||||||
20 | 3 (2 mm2) | |||||
4 (1.25 mm2) | ||||||
5 (1.25 mm2) | ||||||
7 (1.25 mm2) | ||||||
12 (0.5 mm2) | ||||||
24 | 4 (2 mm2) | |||||
5 (2 mm2) | ||||||
10 (1.25 mm2) | ||||||
14 (0.5 mm2) | ||||||
16 (0.5 mm2) | ||||||
28 | 16 (1.25 mm2) | |||||
24 (0.5 mm2) | ||||||
PFPF (Female / Female) PFPM (Female / Male) PMPM (Male / Male) ADFPF (Relay Female / Female) ADFPM (Relay Female / Male) ADMPF (Male Relay / Female) ADMPM (Male Relay / Male) ADFADF (Relay Female /Relay Female) ADMADM (Male Relay / Male Relay) | 16 | 3 (1.25 mm2) | ||||
5 (0.5 mm2) | ||||||
20 | 3 (2 mm2) | |||||
4 (1.25 mm2) | ||||||
5 (1.25 mm2) | ||||||
7 (1.25 mm2) | ||||||
12 (0.5 mm2) | ||||||
24 | 4 (2 mm2) | |||||
5 (2 mm2) | ||||||
10 (1.25 mm2) | ||||||
14 (0.5 mm2) | ||||||
16 (0.5 mm2) | ||||||
28 | 16 (1.25 mm2) | |||||
24 (0.5 mm2) |
Shape Specification Type | Shell Size | Number of Cores |
PF | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PM | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
RF | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
RM | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADF | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADM | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PFT | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PMT | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
RFT | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
RMT | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADFT | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADMT | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PFY | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PMY | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
RFY | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
RMY | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADFY | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADMY | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PFR | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PMR | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
RFR | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
RMR | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADFR | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADMR | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 |
Shape Specification Type | Shell Size | Number of Cores |
PFPF | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PFPM | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
PMPM | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADFPF | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADFPM | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADMPF | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADMPM | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADFADF | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 | ||
ADMADM | 16 | 3 |
5 | ||
20 | 3 | |
4 | ||
5 | ||
7 | ||
12 | ||
24 | 4 | |
5 | ||
10 | ||
14 | ||
16 | ||
28 | 16 | |
24 |
Connector Type (Shell Size - Number of Cores) | Connector | A Cable | D Cable | E Cable | F Cable | G Cable | |||||||||||
Rated Current (A or less) | Rated Voltage (V or less) | Section Area | Rated Voltage | Allowable Current A (30°C) | Section Area | Rated Voltage | Allowable Current A (30°C) | Section Area | Rated Voltage | Allowable Current A (30°C) | Section Area | Rated Voltage | Allowable Current A (30°C) | Section Area | Rated Voltage | Allowable Current A (30°C) | |
16-3 | 10 | 125 | 1.25 mm2 (AWG16) | 300V | 12 | 1.25 mm2 (AWG16) | 300V | 9 | AWG25 (0.2 mm2) | 150V | 4.1 | AWG16 (1.25 mm2) | 300V | 13 | AWG25 (0.2 mm2) | 150V | 3.8 |
16-5 | 5 | 0.5 mm2 (AWG20) | 4 | 0.5 mm2 (AWG20) | 2 | 3.1 | AWG20 (0.5 mm2) | 5 | 2.8 | ||||||||
20-3 | 15 | 250 | 2.0 mm2 (AWG14) | 17 | 2.0 mm2 (AWG14) | 13 | 4.1 | AWG14 (2.0 mm2) | 19 | 3.8 | |||||||
20-4 | 10 | 1.25mm2 (AWG16) | 12 | 1.25mm2 (AWG16) | 8 | 3.7 | AWG16 (1.25mm2) | 12 | 3.3 | ||||||||
20-5 | 10 | 8 | 6 | 3.1 | 9 | 2.8 | |||||||||||
20-7 | 10 | 7 | 6 | 2.7 | 8 | 2.5 | |||||||||||
20-12 | 5 | 0.5 mm2 (AWG20) | 3 | 0.5 mm2 (AWG20) | 2 | 2.1 | AWG20 (0.5 mm2) | 3 | 1.9 | ||||||||
24-4 | 15 | 2.0mm2 (AWG14) | 17 | 2.0mm2 (AWG14) | 11 | 3.7 | AWG14 (2.0 mm2) | 16 | 3.3 | ||||||||
24-5 | 15 | 10 | 9 | 3.1 | 13 | 2.8 | |||||||||||
24-10 | 10 | 1.25 mm2 (AWG16) | 6 | 1.25 mm2 (AWG16) | 5 | 2.5 | AWG16 (1.25 mm2) | 7 | 2.3 | ||||||||
24-14 | 5 | 0.5mm2 (AWG20) | 3 | 0.5mm2 (AWG20) | 1 | 2.1 | AWG20 (0.5mm2) | 3 | 1.9 | ||||||||
24-16 | 5 | 1 | 1.9 | 1.7 | |||||||||||||
28-16 | 10 | 1.25 mm2 (AWG16) | 5 | 1.25 mm2 (AWG16) | 4 | 1.9 | AWG16 (1.25 mm2) | 5 | |||||||||
28-24 | 5 | 0.5 mm2 (AWG20) | 3 | 0.5 mm2 (AWG20) | 1 | 1.6 | AWG20 (0.5 mm2) | 2 | 1.4 |
Part Number |
---|
RNJC-ADFPM-16-3-A-[0.2-50/0.1] |
RNJC-ADFPM-16-5-A-[0.2-50/0.1] |
RNJC-ADFPM-20-3-A-[0.2-50/0.1] |
RNJC-ADFPM-20-4-A-[0.2-50/0.1] |
RNJC-ADFPM-20-5-A-[0.2-50/0.1] |
RNJC-ADFPM-20-7-A-[0.2-50/0.1] |
RNJC-ADFPM-20-12-A-[0.2-50/0.1] |
RNJC-ADFPM-24-4-A-[0.2-50/0.1] |
RNJC-ADFPM-24-5-A-[0.2-50/0.1] |
RNJC-ADFPM-24-10-A-[0.2-50/0.1] |
RNJC-ADFPM-24-14-A-[0.2-50/0.1] |
RNJC-ADFPM-24-16-A-[0.2-50/0.1] |
RNJC-ADFPM-28-16-A-[0.2-50/0.1] |
RNJC-ADFPM-28-24-A-[0.2-50/0.1] |
RNJC-ADMPM-16-3-A-[0.2-50/0.1] |
RNJC-ADMPM-16-5-A-[0.2-50/0.1] |
RNJC-ADMPM-20-3-A-[0.2-50/0.1] |
RNJC-ADMPM-20-4-A-[0.2-50/0.1] |
RNJC-ADMPM-20-5-A-[0.2-50/0.1] |
RNJC-ADMPM-20-7-A-[0.2-50/0.1] |
RNJC-ADMPM-20-12-A-[0.2-50/0.1] |
RNJC-ADMPM-24-4-A-[0.2-50/0.1] |
RNJC-ADMPM-24-5-A-[0.2-50/0.1] |
RNJC-ADMPM-24-10-A-[0.2-50/0.1] |
RNJC-ADMPM-24-14-A-[0.2-50/0.1] |
RNJC-ADMPM-24-16-A-[0.2-50/0.1] |
RNJC-ADMPM-28-16-A-[0.2-50/0.1] |
RNJC-ADMPM-28-24-A-[0.2-50/0.1] |
RNJC-PFPM-16-3-A-[0.2-50/0.1] |
RNJC-PFPM-16-3-G-[0.2-50/0.1] |
RNJC-PFPM-16-5-A-[0.2-50/0.1] |
RNJC-PFPM-16-5-G-[0.2-50/0.1] |
RNJC-PFPM-20-3-A-[0.2-50/0.1] |
RNJC-PFPM-20-3-G-[0.2-50/0.1] |
RNJC-PFPM-20-4-A-[0.2-50/0.1] |
RNJC-PFPM-20-4-G-[0.2-50/0.1] |
RNJC-PFPM-20-5-A-[0.2-50/0.1] |
RNJC-PFPM-20-5-G-[0.2-50/0.1] |
RNJC-PFPM-20-7-A-[0.2-50/0.1] |
RNJC-PFPM-20-7-G-[0.2-50/0.1] |
RNJC-PFPM-20-12-A-[0.2-50/0.1] |
RNJC-PFPM-20-12-G-[0.2-50/0.1] |
RNJC-PFPM-24-4-A-[0.2-50/0.1] |
RNJC-PFPM-24-4-G-[0.2-50/0.1] |
RNJC-PFPM-24-5-A-[0.2-50/0.1] |
RNJC-PFPM-24-5-G-[0.2-50/0.1] |
RNJC-PFPM-24-10-A-[0.2-50/0.1] |
RNJC-PFPM-24-10-G-[0.2-50/0.1] |
RNJC-PFPM-24-14-A-[0.2-50/0.1] |
RNJC-PFPM-24-14-G-[0.2-50/0.1] |
RNJC-PFPM-24-16-A-[0.2-50/0.1] |
RNJC-PFPM-28-16-A-[0.2-50/0.1] |
RNJC-PFPM-28-16-G-[0.2-50/0.1] |
RNJC-PFPM-28-24-A-[0.2-50/0.1] |
RNJC-PMPM-16-3-A-[0.2-50/0.1] |
RNJC-PMPM-16-3-G-[0.2-50/0.1] |
RNJC-PMPM-16-5-A-[0.2-50/0.1] |
RNJC-PMPM-16-5-G-[0.2-50/0.1] |
RNJC-PMPM-20-3-A-[0.2-50/0.1] |
RNJC-PMPM-20-3-G-[0.2-50/0.1] |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | CN1 | CN2 | Number Of Cores | Cable rated voltage (V) | Shipping Date | Shell size | Shield | Cable standard (UL/CSA) | Cable color | Twisted pair | Conductor dimensions (AWG) | Environment resistant | Bend tolerant | Cable type | Specified Length (M) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [3] 3 | 300 | - | 16 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [5] 5 | Less than 100 | - | 16 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [3] 3 | 300 | - | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [5] 5 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [7] 7 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 12 | Less than 100 | - | 20 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 4 | 300 | - | 24 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [5] 5 | 300 | - | 24 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 10 | 300 | - | 24 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 14 | Less than 100 | - | 24 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [16] 16 | Less than 100 | - | 24 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | [16] 16 | 300 | - | 28 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female relay straight | Male straight | 24 | Less than 100 | - | 28 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [3] 3 | 300 | - | 16 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [5] 5 | Less than 100 | - | 16 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [3] 3 | 300 | - | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [5] 5 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [7] 7 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 12 | Less than 100 | - | 20 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 4 | 300 | - | 24 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [5] 5 | 300 | - | 24 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 10 | 300 | - | 24 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 14 | Less than 100 | - | 24 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [16] 16 | Less than 100 | - | 24 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | [16] 16 | 300 | - | 28 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male relay straight | Male straight | 24 | Less than 100 | - | 28 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [3] 3 | 300 | - | 16 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [3] 3 | 150 | - | 16 | 1 Layer | UL | Navy | N/A | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | Less than 100 | - | 16 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 150 | - | 16 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [3] 3 | 300 | - | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [3] 3 | 150 | - | 20 | 1 Layer | UL | Navy | N/A | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 4 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 4 | 150 | - | 20 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 150 | - | 20 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [7] 7 | 300 | - | 20 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [7] 7 | 150 | - | 20 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 12 | Less than 100 | - | 20 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 12 | 150 | - | 20 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 4 | 300 | - | 24 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 4 | 150 | - | 24 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 300 | - | 24 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [5] 5 | 150 | - | 24 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 10 | 300 | - | 24 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 10 | 150 | - | 24 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 14 | Less than 100 | - | 24 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 14 | 150 | - | 24 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [16] 16 | Less than 100 | - | 24 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [16] 16 | 300 | - | 28 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | [16] 16 | 150 | - | 28 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Female straight | Male straight | 24 | Less than 100 | - | 28 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male straight | Male straight | [3] 3 | 300 | - | 16 | N/A | N/A | Gray | N/A | 16 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male straight | Male straight | [3] 3 | 150 | - | 16 | 1 Layer | UL | Navy | N/A | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male straight | Male straight | [5] 5 | Less than 100 | - | 16 | N/A | N/A | Gray | N/A | 20 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male straight | Male straight | [5] 5 | 150 | - | 16 | 1 Layer | UL | Navy | Included | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male straight | Male straight | [3] 3 | 300 | - | 20 | N/A | N/A | Gray | N/A | 14 | N/A | N/A | A | 0.2 ~ 50 | ||
- | 1 Piece(s) | 6 Day(s) or more | Male straight | Male straight | [3] 3 | 150 | - | 20 | 1 Layer | UL | Navy | N/A | 25 | Oil-resistant | Flexible | G | 0.2 ~ 50 |
Loading...
JIS Standard Medium-sized Connector (NJC)
Features
● It has acquired the PSE mark (Electrical Appliance and Material Safety Act Compliant) and can be used widely from power supply to signal transmission.JIS C 5432 Compatible Series Names of Other Manufacturers
Manufacturer Name | Series Name |
---|---|
Nanaboshi Electric Mfg. Co, Ltd. | NJC Series |
Japan Aviation Electronics Industry, Ltd. | SRCN Series |
Hirose Electric Co., Ltd. | JR Series |
TAJIMI ELECTRONICS CO., LTD. | TRC01 Series |
Sanwa Denki Kogyo Co., Ltd. | SNS16 Series (3-core, 5-core) |
ITT Cannon Corporation | JC Series |
DDK Ltd. | JM Series |
Misumi Inc. | MJC Series |
Common Specifications
Material / Finish
Item | Materials | Finish |
---|---|---|
Shell / Dustproof Cap | Zinc Alloy | Satin chrome-plated (NJC) Chrome-plated (MJC) |
Aluminum Alloy (Shell Size 28) | ||
Insulator | Synthetic Resin | ー |
Contact | Copper Alloy | Silver-plated (NJC) Gold-plated (MJC) |
Characteristics
Item | Characteristics | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rated Current | See table below | |||||||||||||||||||
Rated Voltage | See table below | |||||||||||||||||||
Withstand Voltage | No abnormality such as short circuiting occurs when regulated voltage is applied for 1 minute between immediately adjacent conductors. | |||||||||||||||||||
Insulation Resistance | 1,000 MΩ or higher when measured between immediately adjacent conductors with regulated voltage. | |||||||||||||||||||
Contact Resistance | Conductor resistance is 5 mΩ or less when a pair of contacts are connected at up to the regulation length. | |||||||||||||||||||
Vibration Resistance | No functional defect was found during the JIS C 5025 vibration test. Contact resistance is 5 mΩ or less. | |||||||||||||||||||
Impact Resistance | No functional defect was found during the JIS C 5026 shock test. Contact resistance is 5 mΩ or less. | |||||||||||||||||||
Repeated Operation | No functional defect was found when a removal and insertion sequence was tested 500 times. Contact resistance is 5 mΩ or less. | |||||||||||||||||||
Humidity Resistance | No functional defect was found during the JIS C 5023 humidity test. Insulation resistance is 100 MΩ or higher. | |||||||||||||||||||
Temperature Cycle | No functional defect was found during the JIS C 5030 temperature cycle test. | |||||||||||||||||||
Corrosion Resistance | No functional defect was found during the JIS C 5028 salt water spray test. Contact resistance is 5 mΩ or less. | |||||||||||||||||||
Allowable Operating Temperature Range |
|
Product No. | Shell Size |
Number of Cores | Rated Current (A or less) |
Rated Voltage (V or less) |
Withstand Voltage AC (V) |
Insulation Resistance (MΩ or higher) |
Contact Resistance (mΩ or less) |
Compatible Wire Size | Applicable Electric Wire Finished Outer Diameter (mm) |
|
---|---|---|---|---|---|---|---|---|---|---|
AWG | Conductor Section Area mm2 | |||||||||
NJC | 16 | 3 | 10 | 125 | 1,500 | 2,000 | 3 | 16 | 1.25 | 7.0 ~ 8.5 |
5 | 5 | 1,000 | 1,000 | 5 | 20 | 0.5 | ||||
NJC/MJC | 20 | 2,3 | 15 | 250 | 1,500 | 2,000 | 3 | 14 | 2 | 10.0 ~ 12.5 |
4,5 | 10 | 16 | 1.25 | |||||||
7 | 1,000 | |||||||||
12 | 5 | 1,000 | 5 | 20 | 0.5 | |||||
24 | 2,3 | 20 | 250 | 1,500 | 5,000 | 3 | 12 | 3.5 | 11.5 ~ 14.0 | |
4,5 | 15 | 14 | 2 | |||||||
10 | 10 | 1,000 | 2,000 | 16 | 1.25 | |||||
14, 16 | 5 | 1,000 | 5 | 20 | 0.5 | |||||
28 | 16 | 10 | 250 | 1,000 | 2,000 | 3 | 16 | 1.25 | 13.6 ~ 16.5 | |
24 | 5 | 1,000 | 5 | 20 | 0.5 |
Contact Arrangement Diagram
Connection Work Method
Connector type | NJC | Connector manufacturer | Nanaboshi Electric Mfg. Co., Ltd. | Cable shape | Circular |
---|
How can we improve?