(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Dsub connector EMI countermeasure product/general-purpose product Resin hood (MDA-50H-UNC)

Dsub connector EMI countermeasure product/general-purpose product Resin hood MDA-50H-UNC

Click this image to zoom it.

Move the mouse over the image to zoom

  • Dsub connector EMI countermeasure product/general-purpose product Resin hood
  • Dsub connector EMI countermeasure product/general-purpose product Resin hood
  • Dsub connector EMI countermeasure product/general-purpose product Resin hood
  • Volume Discount

[Features]A general-purpose resin hood for EMI (electromagnetic interference) countermeasures that achieves low prices. There are 2 types of mounting screws, a short screw type that can be fixed with a screwdriver and a long screw type that can be operated by hand, making it easy to fix. Each has M2.6 [metric thread] and #4-40 [imperial thread], so you can choose according to your application.


● For the fixing screws, short screw model to be fixed by a screwdriver and long screw model that can be fixed by hand are available. For each, select from M2.6 and #4-40 according to the application.


· This hood cannot be used for the following connectors.
EMI Pressure Welding D-sub

High Current D-sub

PDF

Japanese Only

Specifications

EMI Countermeasures D-Sub Connector with Resin Hood:Related Image

Model NumberNumber of Cores
Parentheses show high-density type
With/Without
Plating
Screw
Type
Weight
g
MDA-9H-M2.69 (15)With PlatingM2.6 Short14.0
MDA-15H-M2.615 (26)15.5
MDA-25H-M2.625 (44)20.5
MDA-37H-M2.637 (62)24.5
MDA-50H-M2.650 (78)23.0
MDA-9H-UNC9 (15)#4-40 Short14.0
MDA-15H-UNC15 (26)15.5
MDA-25H-UNC25 (44)20.5
MDA-37H-UNC37 (62)24.5
MDA-50H-UNC50 (78)23.0
RDA-9H-M2.69 (15)Without PlatingM2.6 Short14.0
RDA-15H-M2.615 (26)15.5
RDA-25H-M2.625 (44)20.5
RDA-37H-M2.637 (62)24.5
RDA-50H-M2.650 (78)23.0
RDA-9H-UNC9 (15)#4-40 Short14.0
RDA-15H-UNC15 (26)15.5
RDA-25H-UNC25 (44)20.5
RDA-37H-UNC37 (62)24.5
RDA-50H-UNC50 (78)23.0
RDA-9HT-M2.69 (15)M2.6 Long17.5
RDA-15HT-M2.615 (26)19.0
RDA-25HT-M2.625 (44)24.5
RDA-37HT-M2.637 (62)28.0
RDA-50HT-M2.650 (78)26.5
RDA-9HT-UNC9 (15)#4-40 Long17.5
RDA-15HT-UNC15 (26)19.0
RDA-25HT-UNC25 (44)24.5
RDA-37HT-UNC37 (62)28.0
RDA-50HT-UNC50 (78)26.5

More Information

EMI Countermeasures D-Sub Connector with Resin Hood:Related Image

EMI Countermeasures D-Sub Connector with Resin Hood:Related Image

Material / Finish

ItemMaterialFinish
HoodABS Resin, UL-94HBGray color
Hood (EMI Countermeasure Product)ABS Resin, UL-94VONickel-plated Silver
Cable ClampSteelNickel-plated
Fixing Screws for Bonding

Part Number
MDA-50H-UNC
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber of Pins Cable pullout direction Screw type

SGD 8.61

1 Piece(s)Available 4 Day(s) or more 50 ~ 78Straight#4-40

Loading...

  1. 1

 

Compatible Wire Size

Connector TypeCompatible Wire Size
AWG SizeConductor Cross-Sectional Area (mm2)
Solder Connection TypeFiner than 20Less than 0.53
Pressure Weld Connection Type1.27 mm Pitch 28 Flat Cable
High-density Solder Connection Type22 ~ 280.08 ~ 0.32
Terminal Block Built in Type14 ~ 262.0 ~ 1.5
High Current TypeFor 10A16 ~ 120.3 ~ 1.25
For 20A12 ~ 180.75 ~ 3.5
・ When mounting a hood, the wires in the table at left may not be usable, depending on the cable extraction port diameter. Use with due attention to the cable finished outer diameter, etc.

Panel Size

Solder Connection / Pressure Weld Connection Type
● Dimension Table
Number of CoresA±0.15B±0.2C±0.2
High Current TypeHigh-density typeOthers
-15924.9920.612.0
3261533.3228.812.0
5442547.0442.612.0
8623763.5059.012.0
-785061.1156.615.2
Mounting holes for panel front and rear mounting are common.

Pressure Weld Connection Type

a. Dimensions when mounting the connector from panel front
● Dimension Table
Number of CoresA1B1
924.9922.00
1533.3230.30
2547.0444.00
3763.0560.50
b. Dimensions when mounting the connector from panel rear
● Dimension Table
Number of CoresA2B2
924.9920.20
1533.3228.60
2547.0442.50
3763.0559.20

Contact Arrangement Diagram

Shell Size GroupEABCD
Standard Type
High-density type

Basic Information

Connector Shape Square shape Connector series initials D/E/F D/E/F Dsub
Protection function (environmentally resistant) None

Please check the type/dimensions/specifications of the part MDA-50H-UNC in the Dsub connector EMI countermeasure product/general-purpose product Resin hood series.

Similar Part Numbers

Part Number
MDA-25H-UNC
MDA-37H-M2.6
MDA-37H-UNC
MDA-9H-M2.6
MDA-9H-UNC
RDA-15H-M2.6
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipNumber of Pins Cable pullout direction Screw type

SGD 6.34

1 Piece(s)Available 4 Day(s) or more 25 ~ 44Straight#4-40

SGD 6.80

1 Piece(s)Available 4 Day(s) or more 37 ~ 62StraightM2.6

SGD 7.70

1 Piece(s)Available 4 Day(s) or more 37 ~ 62Straight#4-40

SGD 4.42

1 Piece(s)Available 4 Day(s) or more 9 ~ 15StraightM2.6

SGD 4.86

1 Piece(s)Available 4 Day(s) or more 9 ~ 15Straight#4-40

SGD 2.90

1 Piece(s)Available 4 Day(s) or more 15 ~ 26-M2.6 Short

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)