Distribution Board, Ground Leakage Breaker

Distribution Board, Ground Leakage Breaker
  • On Sale Till 31/03/2025
  • Volume Discount

Compact, Space-saving, ground Leakage Breakers for Distribution Boards

  • IEC
  • JIS
  • PSE Law

● DIN rail mounting is possible.
● The panelboard type is compact, allowing it to be used as a distribution panel.
● The lineup now includes 5A ~ 100A rated current.
● JIS Agreement dimensions are 96 mm height and 60 mm depth.
● Accessory equipment can be easily mounted.
● Select from breaking capacity of 5 kA and 10 kA.

Specifications

Distribution Board, Ground Leakage Breaker:Related Image

TypeAmpere FrameNumber of PhasesRated Breaking CurrentRated CurrentSensitivity CurrentModel
(220 V)
Distribution Panel Type
(for distribution panel)
30ASingle-phase5kA5A30mAEBS-32FB-5A
10AEBS-32FB-10A
15AEBS-32FB-15A
20AEBS-32FB-20A
30AEBS-32FB-30A
50A40AEBS-52FB-40A
50AEBS-52FB-50A
100A10kA60AEBS-102FB-60A
75AEBS-102FB-75A
100AEBS-102FB-100A
60A100mAEBS-102FB-60A-100MA
75AEBS-102FB-75A-100MA
100AEBS-102FB-100A-100MA
30AThree-phase5kA5A30mAEBS-33FB-5A
10AEBS-33FB-10A
15AEBS-33FB-15A
20AEBS-33FB-20A
30AEBS-33FB-30A
50A40AEBS-53FB-40A
50AEBS-53FB-50A
100A10kA60AEBS-103FB-60A
75AEBS-103FB-75A
100AEBS-103FB-100A
60A100mAEBS-103FB-60A-100MA
75AEBS-103FB-75A-100MA
100AEBS-103FB-100A-100MA

More Information

Specifications
Ampere Frame30AF50AF100AF
TypePanelboard Type
ModelEBS-32FBEBS-33FBEBS-52FBEBS-53FBEBS-102FBEBS-103FB
RatingPole Number232323
Pole Number / Number of Elements2P2E3P3E2P2E3P3E2P2E3P3E
Protective FunctionOverload
Short-circuit Protection Combined Use
Overload
Short-circuit Protection Combined Use
Overload
Short-circuit Protection Combined Use
Rated Voltage AC (V)100 ~ 220100 ~ 220100 ~ 220
Rated Voltage DC (V)---
Rated Insulation Voltage (V)220220220
Withstand Voltage200020002000
Rated Current (A)5,10, 15,20, 3040,5060,75,100
Rated Sensitivity Current (mA)303030,100
Operating Time (sec)Within 0.1Within 0.1Within 0.1
Rated Breaking Capacity (KA)
KSC8321,IEC60947-2
220 VAC5510
100/110 VAC5510
Outline Drawing (mm)
Distribution Board, Ground Leakage Breaker:Related Image
a5075507575
b969696
c606060
d808080
Product Weight (kg)0.330.440.330.440.460.6
Overcurrent Tripping SystemFull Electromagnetic TypeFull Electromagnetic TypeFull Electromagnetic Type
Installation ConfigurationScrew and DIN Rail Mounting *1Screw and DIN Rail Mounting *1Screw and DIN Rail Mounting *1
Terminal Block Screw SizeM5M5M8
Tightening Torque2.2 ~ 2.7 N·m2.2 ~ 2.7 N·m5.4 ~ 7.3 N·m
Auxiliary EquipmentAuxiliary Contact AXMountableMountableMountable
Alarm Contact AL
External Operating Handle D (Surface Mounting)Non-MountableNon-MountableNon-Mountable
External Operating Handle E (Extending)
Terminal CoverMountableMountableMountable
Standard AcquiredElectrical Appliance and Material Safety ActAcquiredAcquiredAcquired
IEC60947-2AcquiredAcquiredAcquired
JISAcquiredAcquiredAcquired
*1: 2 mounting screws are included as standard.


· This product does not come with the terminal cover.
Please purchase it separately as needed.

■Release Notes
Regarding the connection of the breaker, do not perform the reverse connection as the commodity guarantee will be invalid.
The displayed specifications have been inspected in correct connection and given the product warranty.

Distribution Board, Ground Leakage Breaker:Related Image

Inspection after Shutdown
When a breaker shutdown occurs due to accident current, the fuse may be reused or may need to be replaced depending on the situation.
Magnitude of breaking currentDegree of breaker damageMeasures
Operation within time delay tripping
(Overcurrent within approx. 10 times the rated current)
No abnormality other than exhaust portCan break overcurrent of 6 times the rated current for up to 50 times
(100 A or lower)
Relatively low current value
Shorting Current
Distribution Board, Ground Leakage Breaker:Related Image
Large shorting current close to rated breaking capacity
Carbonization around exhaust port can be observed
Distribution Board, Ground Leakage Breaker:Related Image
Carbonization around handle
Carbonization around exhaust port
Fused metal deposit inside breaker
Can be Reused
Distribution Board, Ground Leakage Breaker:Related Image
Replace with New Parts
∙ Perform insulation withstand voltage test if insulation resistance value does not reach 5 MΩ.
∙ Can be used temporarily if the standard withstand voltage is achieved, but an early replacement is recommended.
∙ Can be used if both insulation resistance and withstand voltage are sufficient, but check temperature increase does not occur for a certain period of time.
∙ Perform an operation test of the leakage breaker using the test button.
Part Number
EBS-32FB-5A
EBS-32FB-10A
EBS-32FB-15A
EBS-32FB-20A
EBS-32FB-30A
EBS-33FB-5A
EBS-33FB-10A
EBS-33FB-15A
EBS-33FB-20A
EBS-33FB-30A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAmpere frame AF Rated block capacity AC 200 V
(kA)
Number of Poles Rated Current
(A)
rate sensitivity current
(mA)
Dimension width
(mm)

SGD 48.34

1 Piece(s)Available Same day 30AF5253050

SGD 48.34

1 Piece(s)Available Same day 30AF52103050

SGD 48.34

1 Piece(s)Available Same day 30AF52153050

SGD 48.34

1 Piece(s) Same day 30AF52203050

SGD 48.34

1 Piece(s)Available Same day 30AF52303050

SGD 60.55

1 Piece(s)Available 4 Day(s) or more 30AF5353075

SGD 60.55

1 Piece(s)Available 4 Day(s) or more 30AF53103075

SGD 60.55

SGD 12.11

1 Piece(s)Available Same day 30AF53153075

SGD 60.55

1 Piece(s)Available 4 Day(s) or more 30AF53203075

SGD 60.55

SGD 12.11

1 Piece(s)Available Same day 30AF53303075

Loading...

  1. 1

Drawing

Distribution Board, Ground Leakage Breaker:Related Image

Basic Information

Rated Operating Voltage(V) 220 Mounting Method DIN rail mount Representative Standard PSE
Dimension height(mm) 96 Dimension depth(mm) 75.5 Rated block capacity, voltages except VAC 100/200/400, VDC 250 Present
Connection Method Surface form Other standards (IEC) Other standards (KEMA)
Notes Rated breaking capacity is the value at 220 VAC