(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 24/11/2024 to 7:00 (SGT) 25/11/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Contact

Contact

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

It is a low-priced contactor with the world's longest open-close lifespan. Accessories can be easily installed.

  • CE-Compliant
  • EN
  • VDE
  • BS
  • IEC
  • Screw Mounted
  • DIN Rail

● The electromagnetic contactor is now on sale at a low price.
● This CE Marking compliant product has passed certification testing.
● Terminal cover is standard equipment.
● World's Longest Switching Life EC60947-4-1 (JIS C 8201-4-1, JEM1038)
Electrical life 2.5 million operations (Europe Company A, 2 million operations, Japan Company B 2 million operations)
Mechanical life 25 million operations (Europe Company A, 16 million operations, Japan Company B 10 million operations)

PDF

Specifications

Contact:Related Image

Frame Size
(AF)
Coil VoltageAuxiliary ContactMotor Capacity
(KW)
Model
AC-3
200/240V
18200 VAC1a2.2MCR-6A-AC200V
100 VACMCR-6A-AC100V
24 VDCMCR-6A-DC24V
22200 VAC1a1b2.5MCR-9B-AC200V
100 VACMCR-9B-AC100V
24 VDCMCR-9B-DC24V
200 VAC3.5MCR-12B-AC200V
100 VACMCR-12B-AC100V
24 VDCMCR-12B-DC24V
200 VAC4.5MCR-18B-AC200V
100 VACMCR-18B-AC100V
24 VDCMCR-18B-DC24V
200 VAC5.5MCR-22B-AC200V
100 VACMCR-22B-AC100V
24 VDCMCR-22B-DC24V
40200 VAC7.5MCR-32A-AC200V
100 VACMCR-32A-AC100V
65200 VAC15MCR-50A-AC200V
100 VACMCR-50A-AC100V
200 VAC18.5MCR-65A-AC200V
100 VACMCR-65A-AC100V

More Information

Specifications
ModelMCR-6AMCR-9BMCR-12BMCR-18BMCR-22BMCR-32AMCR-50AMCR-65A
Rated Operating Voltage690V690V
Rated Insulation Voltage690V1000V
Rated Frequency50 / 60 Hz50/60Hz
Rated Impulse
Withstand Voltage
6 KV8KV
Maximum Number of Operations per Hour1800/hour1800/hour
Mechanical Life15 million operations12 million operations
Electrical Life2.5 million operations2 million operations
Current, Power AC-125252532405070100
AC-3
200/240V KW
2.22.53.54.55.57.51518.5
A911131822325565
380/440V KW345.57.511152230
A79121822325065
500/550V KW347.57.51518.53033
A67121320284360
690V KW347.57.51518.53033
A469918202835
UL Rated Continuous Current A25252540405070100
Single-phase 110 ~ 120V HP0.50.50.7512235
220 ~ 240V HP1.51.523351015
Three-phase 200 ~ 208V HP22357.57.52025
220 ~ 240V HP3357.510102530
440 ~ 480V HP557.51015204050
550 ~ 600 V HP7.57.5101520255060
AC Coil Weight kg0.330.340.551.05
Size (W x H x D)
mm
45*73.5
*82
45*73.5*8669*83
*93
79*106*122
DC Coil Weight kg0.50.510.771.3
Size (W x H x D)
mm
45*83
*113.7
45*73.5*117.769*83
*120
79*106*149

■AC Coil
ModelMCR-6AMCR-9BMCR-32AMCR-50A
MCR-12BMCR-65A
MCR-18B
MCR-22B
Operation Voltage50 Hz (V)100,200V
60 Hz (V)100,200V
50 / 60Hz (V)100,200V
Clamping VoltagePickup85 ~ 110% (50 Hz)
85 ~ 110%(60 Hz)
Dropout30 ~ 60%
Coil
Power Consumption
     
220 VACInrush Current (VA)58/5658/5653/50110/104
50/60HzRated Power (VA)9.0/6.09.0/6.012.0/9.013.0/10.0
Operating TimeClosed (ms)12...2212...2212...2212...22
Open (ms)4...194...194...194...19

■DC Coil
ModelMCR-6AMCR-9B
MCR-12B
MCR-18B
MCR-22B
Operation Voltage 24V
Clamping VoltagePickup70 ~ 110%
Dropout10 ~ 30%
Coil
Power Consumption
Inrush Current (VA)99
24 VDCRated Power (VA)99
Coil Current(A)0.40.4
Operating TimeClosed (ms)35...5035...50
Open (ms)4...194...19


< Auxiliary Contact Capacity >

■Auxiliary Contact Capacity
 Rated VoltageRated Current
Auxiliary Contact CapacityAC120V6A
AC240V3A
AC380V1.9A
AC480V1.5A
AC500V1.4A
AC600V1.2A
DC125V1.1A
DC250V0.55A
DC400V0.31A
DC500V0.27A
DC600V0.2A

< Wiring Specifications >

Contact:Related Image

< Circuit Diagram >

MCR-6A-□□
Contact:Related Image

MCR-9B-□□~MCR-65A-□□
Contact:Related Image
* Please check the CAD data for the print information of the body.
Part Number
MCR-6A-AC100V
MCR-6A-AC200V
MCR-6A-DC24V
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCoil rated voltage
(V)
Auxiliary Contact Dimension length
(mm)
Dimension width
(mm)
Dimension thickness
(mm)

SGD 19.85

1 Piece(s)Available 4 Day(s) or more AC 1001a73.54582

SGD 19.85

1 Piece(s)Available 4 Day(s) or more AC 2001a73.54582

SGD 31.06

1 Piece(s) Same day DC241a8345113.7

Loading...

  1. 1

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)