Background Suppression Sensors (Part Numbers)

Background Suppression Sensors

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

Economy series Photoelectric Sensors
Photoelectric Sensors are a type of sensor that uses light to detect the presence or absence of an object. They offer a wide variety of type to choose from.
[Feature]
● Shape : Compact
● Detection Distance (mm.) : 20 - 100 and 35-200
● Output Mode : NPN and PNP
[Application]
Photoelectric Sensors are commonly used in industrial applications for example conveyor belts, assembly lines and so on

Product Overview

■ Comparison of MISUMI Photoelectric Sensors Standard Product and Economy Series
 MISUMI Standard Product
MZL-D
Economy Series 
E-MSMLS61N-2M
Output FormatNPNNPN
Detection Distance (mm)30 to 40010 to 300
Response Time250μs or less250μs or less
Consumed CurrentLight Emitter20mA or less25mA or less
Light Receiver
Projected Light SourceRed LEDRed LED
RoHS10CompliantNon-compliant

Dimensional Drawing

Dimension drawing
 

Specification Table

Detection MethodShapeDetection Range
(Paper with White Bottom)
Setting Range
(BGS)
Spot SizeNPN TypePNP TypeOutputAdjustment Method
Distance Setting TypeSpecification Table2~100mm2~100mm2mmE-MSMLS63N-2ME-MSMLS83P-2MN.O/N.C Free SwitchingKnob Type
10~300mm35~200mm20mmE-MSMLS61N-2ME-MSMLS81P-2M

Product Features

Product Features
Product Features
Product Features
Product Features
Product Features
Usage Method

■ I/O circuit diagram
DC 4-wire NPN outputDC 4-wire PNP output
Photoelectric SensorsPhotoelectric Sensors
(Note) When the white line is OFF, the black line operation output is NO.
When ON, the black line operation output becomes NC.
(Note) When the white line is OFF, the black line operation output is NO.
When ON, the black line operation output becomes NC.
Photoelectric SensorsNecessary for confirming passage of workpiece

Precautions

Photoelectric Sensors, This product is intended for use in industrial environments
Note that over-stretching the wire will cause breakage
Perform wiring with the power off

Note that incorrect wiring may damage the Photoelectric Sensors
Use the power supply voltage within the rated range
Ensure that the power supply ground terminal is grounded

For more product information, please scan the following QR code
Features

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
E-MSMLS61N-2M
E-MSMLS63N-2M
E-MSMLS81P-2M
E-MSMLS83P-2M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipDetection Distance
(mm)
Output Mode

SGD 36.28

1 Piece(s)Available Same day 35~200mmNPN

SGD 36.28

1 Piece(s)Available Same day 20~100mmNPN

SGD 36.28

1 Piece(s)Available 5 Day(s) 35~200mmPNP

SGD 36.28

1 Piece(s)Available 5 Day(s) 20~100mmPNP

Loading...

  1. 1
Brand Introduction
Since its establishment in 1963 in Japan, MISUMI Group Inc. has been providing customers with a wide range of high quality parts such as FA factory automation parts, mold parts, electronic parts, tools and consumables in a fast and accurate manner. We have created a low-cost business model by compiling our own catalogs and establishing a marketing system to sell our products directly, and we continue to develop MISUMI branded products with a high level of quality by developing an annual product plan based on customer feedback and requests.
 

Basic Information

Type Photoelectric Sensor Detection Light Type Small Spots Amplifier Installation Type Built-in Type

Frequently asked question (FAQ)

Question: Types of photo microsensors
Answer: The three main types, through-beam, diffuse-reflective and retro-reflective, are selected according to the mode of distance output used for detection.
Question: Mounting Direction
Answer: Be sure to make the detection surface of the photo microsensor and the detection object are horizonta. When detecting the surface of a shiny object, tilt the sensor 5 to 10 degrees before installation.
Question: Difference between optical fiber sensors and photo microsensors
Answer: 1. Fiber optic sensors need to be used with fiber optic amplifiers and feature small detection spot
2. Optical sensors have long detection distance and allow remote detection.