(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Instead, please kindly use other browsers like Google Chrome, Microsoft Edge or Mozilla Firefox.

  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Temperature Sensors - Terminal Selectable, K- / J-Thermocouple

Temperature Sensors - Terminal Selectable, K- / J-Thermocouple

Temperature Sensors - Terminal Selectable, K- / J-Thermocouple
These Temperature Sensors are commonly used in manufacturing and automation machine
[Feature]
● Temperature Sensors : Thermocouple Type K and Type J
● Sheath, Protection Tube Diameter (mm.): 1, 1.6, 3.2 and 4.8
● Protection Tube Length (mm.): The size is configurable between 50 to 1500 mm, and the minimum length can be increased by increments 10 mm.
● Wire Length (m.): The size is configurable between 0.3 to 5 m, and the minimum length can be increased by increments 0.1 m.
● Temperature Range (°C) :
MSFK - 0 to 800 (depend on Sheath diameter)
MSFJ - 0 to 750 (depend on Sheath diameter)
MSFP - 0 to 300 (depend on Sheath diameter)
● Crimp Terminal Type:
MSFK and MSFJ - M4Y-Shaped 2 sets
MSFP - M4Y-Shaped 3 sets
[Application]
It is used in a variety of application such as heat treatment, packaging industry , plastic industry , and so on.

(i)Caution

  • Please check the content on our website as the PDF does not contain the most up-to-date information.
・Materials
MSFK, MSFJMSFKMSFJ
Type of ThermocoupleK ThermocoupleJ Thermocouple
PrecisionJIS Class 2
Temperature Measurement Contact PointIsolated Neutral Type
Temperature Measurement RangeØ1.0, 1.60 ~ 650°C0~450°C
Ø3.20 ~ 750°C0 ~ 650°C
Ø4.80 ~ 800°C0 ~ 750°C
[ M ]MaterialSheathSUS316 or SUS316L
SleeveSUS304
Heat Resistance Temperature of Sleeve80°C
Lead Wire
(Operating Temp. Range)
Glass Wool Coating
(0 ~ 150°C)
MSFP
Type of DevicePt100Ω
PrecisionJIS Class B
Lead Type3-lead Type
Temperature Measurement Range0 ~ 300°C
[ M ]MaterialProtection TubesSUS316
SleeveSUS304
Heat Resistance Temperature of Sleeve80°C
Lead Wire
(Operating Temp. Range)
Vinyl Coating
(-20 ~ 70°C)

Specifications

Part Number-L-F-Terminal
MSFK1.6-170-F2.5-M
■K Thermocouple, J Thermocouple
Part NumberL
10mm Increment
Lead Wire Length F
0.1m Increment
Terminal
TypeD
(K Thermocouple)
MSFK

(J Thermocouple)
MSFJ
1.050~2000.3~5.0N
M
Y
1.650~500
3.250~1000
4.850~1500
■Temperature Measuring Resistor (Pt100Ω)
Part NumberL
10mm Increment
Lead Wire Length F
0.1m Increment
Terminal
TypeD
(Temperature Measuring Resistor)
MSFP
1.650~5000.3~5.0N
M
Y
3.2
4.8

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
MSFJ1.0-[50-200/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFJ1.6-[50-500/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFJ3.2-[50-1000/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFJ4.8-[50-1500/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFK1.0-[50-200/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFK1.6-[50-500/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFK3.2-[50-1000/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFK4.8-[50-1500/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFP1.6-[50-500/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFP3.2-[50-500/10]-F[0.3-5/0.1]-[M,​N,​Y]
MSFP4.8-[50-500/10]-F[0.3-5/0.1]-[M,​N,​Y]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSType of Temperature Sensor Type of Thermocouple Temperature Measurement Contact Point Type of Device Temperature Measuring Resistor Structure Operating Temperature Range
(°C)
Sheath, Protection Tube Diameter
(Ø)
Sheath, Protecting Tube Length L
(mm)
Type of Terminal Lead Wire Insulation Material Lead Wire Length (F)
(m)

-

1 Piece(s) 11 Day(s) or more 10ThermocoupleJ ThermocoupleIsolated Neutral Type--0~150150 ~ 200No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp Terminal-0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10ThermocoupleJ ThermocoupleIsolated Neutral Type--0~1501.650 ~ 500No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp Terminal-0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10ThermocoupleJ ThermocoupleIsolated Neutral Type--0~1503.250 ~ 1000No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp Terminal-0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10ThermocoupleJ ThermocoupleIsolated Neutral Type--0~1504.850 ~ 1500No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp Terminal-0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10ThermocoupleK ThermocoupleIsolated Neutral Type--0~150150 ~ 200No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp Terminal-0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10ThermocoupleK ThermocoupleIsolated Neutral Type--0~1501.650 ~ 500No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp Terminal-0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10ThermocoupleK ThermocoupleIsolated Neutral Type--0~1503.250 ~ 1000No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp Terminal-0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10ThermocoupleK ThermocoupleIsolated Neutral Type--0~1504.850 ~ 1500No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp Terminal-0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10Temperature Measuring Resistor--Pt100ΩProtection Tubes-20~701.650 ~ 500No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp TerminalVinyl Coating0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10Temperature Measuring Resistor--Pt100ΩProtection Tubes-20~703.250 ~ 500No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp TerminalVinyl Coating0.3 ~ 5

-

1 Piece(s) 11 Day(s) or more 10Temperature Measuring Resistor--Pt100ΩProtection Tubes-20~704.850 ~ 500No Crimp Terminal / Round Crimp Terminal / Y-Shaped Crimp TerminalVinyl Coating0.3 ~ 5

Loading...

  1. 1

More Information

[ ! ]The maximum temperature of measurement is only a value of measurement point (end of Sheath). As for the actual temperature measurement, please be careful so that the temperature of Sheath will not excel the heat resistance temperature (80°C). It might cause disconnection because of the swell caused by heat inside the sleeve.
Especially when a heated object temperature exceeds 100°C, a long type of sheath L length is recommended, which is used to put maximum distance between the sleeve and the heated object, or Temperature Sensor, Heat Resistant Type (P.1656) is recommended.
 

Basic Information

Measurement Object Temperature Sensor Sheath, Protecting Tube Material SUS316 Operating Environment Standard
Number of Elements 1 Sheath, Protecting Tube Shape Straight Attaching Portion Shape Sleeve

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)