Temperature Controller (Outer Diameter 48 × 48 mm / Outer Diameter 96 × 96 mm) (MTCTR)

Temperature Controller (Outer Diameter 48 × 48 mm / Outer Diameter 96 × 96 mm) MTCTR

Click this image to zoom it.

Move the mouse over the image to zoom

  • Temperature Controller (Outer Diameter 48 × 48 mm / Outer Diameter 96 × 96 mm)
  • Temperature Controller (Outer Diameter 48 × 48 mm / Outer Diameter 96 × 96 mm)
  • Temperature Controller (Outer Diameter 48 × 48 mm / Outer Diameter 96 × 96 mm)
  • Temperature Controller (Outer Diameter 48 × 48 mm / Outer Diameter 96 × 96 mm)
  • Temperature Controller (Outer Diameter 48 × 48 mm / Outer Diameter 96 × 96 mm)
  • On Sale Till 31/03/2025

Temperature Regulators - Standard Units
Temperature controllers are devices used to adjust the temperature of the controlled device to the set target temperature
[Feature]
● Dimension (Width X Length X Depth) (mm.)
MTCTR, MTCTRD, MTCTS and MTCTSD - 48 x 48 x 83
MTBGR and MTBGS - 96 x 96 x 86
● Input : Thermocouple (K, J, R, T, N, S, B) and Resistance thermometer (Pt100Ω / JPt100Ω.)
● Output : Relay contact output or SSR drive output
● Power Supply Voltage : AC100 ~ 240V
[Application]
It is used to adjust the temperature of the controlled device to the set target temperature

Temperature Regulators - Standard Units:Related Image

Specifications

Part Number
MTCTR
Part NumberMTCTRMTCTS
O.D. Dimension48×48×83
Control MethodON/OFF control, PID Control with Auto Tuning, PID Control with Selfl-tuning
InputThermocouples (K, J, R, T, N, S, B) Temperature Measuring Resistor (Pt100Ω / JPt100Ω.)
Control Output (OUT1)Relay Contact Output
(Contact Capacity AC250V 3A Resistive Load)
SSR Drive Voltage Output
(DC12V Max. 20mA)
Alarm Output (EV1)Relay Contact Output (Contact Capacity AC250V 2.4A Resistive Load) 1a Contact Point
Control / Alarm Output 2
(OUT2/EV2)
Relay Contact Output (Contact Capacity AC250V 2.4A Resistive Load) 1a Contact Point
Sampling Frequency500mS
Indication Accuracy (Thermocouple)The bigger one of ±0.3% of specified value +1 digit or ±2°C
±3°C for -100 ~ 0°C, ±4°C for -200 ~ -100°C,
no regulation for 400°C or less of B Thermocouple
Indication Accuracy (Temperature Measuring Resistor)The bigger one of ±0.3% of specified value +1 digit or ±2°C
Indication Accuracy Maintenance Temperature RangeAmbient Temperature: 23±10°C
Storage ElementEEPROM
Power Supply VoltageAC100 ~ 240V (Allowable Voltage Change Range 85 ~ 264V)
Power Consumption10VA (max.)
Mass180g or Less

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
MTCTR
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSControl Output External Size (A) Heater Breakage Alarm Function

SGD 126.35

1 Piece(s) Same day 10Relay Contact Output48 x 48mmNot Provided

Loading...

  1. 1

More Information

Temperature Regulators - Standard Units:Related Image
Temperature Regulators - Standard Units:Related Image
Temperature Regulators - Standard Units:Related Image
Temperature Regulators - Standard Units:Related Image
Be sure to refer to "Precautions on Wire Connection" and "Operating Environment" on >>P.2443.
 

Basic Information

Control Method ON-OFF Control / PID Control with Self-Tuning Number of Control Points 1 Number of Input Points(pcs.) 1
Setting Method Key Input Power Supply Voltage 100::240 Failure Detecting Function Heater Overcurrent

Please check the type/dimensions/specifications of the part MTCTR in the Temperature Controller (Outer Diameter 48 × 48 mm / Outer Diameter 96 × 96 mm) series.

Similar Part Numbers

Part Number
MTBGR
MTBGS
MTCTRD
MTCTS
MTCTSD
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSControl Output External Size (A) Heater Breakage Alarm Function

SGD 235.85

1 Piece(s) 4 Day(s) or more 10Relay Contact Output96 x 96mmNot Provided

SGD 235.85

1 Piece(s) 4 Day(s) or more 10SSR Drive Voltage Output96 x 96mmNot Provided

SGD 244.27

1 Piece(s) 4 Day(s) or more 10Relay Contact Output48 x 48mmProvided

SGD 126.35

1 Piece(s) Same day 10SSR Drive Voltage Output48 x 48mmNot Provided

SGD 244.27

1 Piece(s) Same day 10SSR Drive Voltage Output48 x 48mmProvided

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(65) 6733 7211 / FAX:(65) 6733 0211
9:00am - 6:00pm (Monday - Friday)